WEPMA050 BPM (Beam Position Monitor) in the PAL Linac and BTL 393
 
  • S.-C. Kim, J. Choi, Y. J. Han, J. Y. Huang, D. T. Kim, W. W. Lee, H. J. Park
    PAL, Pohang, Kyungbuk
 
  In Aug. 2004, thirteen BPMs are installed at BTL (Beam Transport Line), and later in Aug. 2005, three BPM installed at main linac for beam trajectory measurement and feedback. BPMs for the BTL consist of 100mm strip-line electrodes in 150mm long chamber and uses SMA-R type feed-throughs. BPMs of the Linac consist of 57mm strip-line electrodes in 100mm short chamber and SMA-R type feed-throughs. 500MHz log-ratio signal processing circuits are used for the Linac and BTL BPM electronics. BPM data acquisition system is developed as an EPICS IOC by using NI S-series DAQ board and NI LabView 7.1. Best read-out accuracy of BPM system is measured as 20mm including BPM electronics. In this paper, we describe on the status of the BPM and its characteristics for PAL Linac and BTL.