THPMA067 Stability Analysis of a Klystron-Modulator for PAL XFEL 729
 
  • J.-S. Oh, C. W. Chung, S. D. Jang, S. J. Kwon, Y. G. Son, J.-H. Suh
    PAL, Pohang, Kyungbuk
  • I. S. Ko, W. Namkung
    POSTECH, Pohang, Kyungbuk
 
  The PAL (Pohang Accelerator Laboratory) is persuading to construct a SASE-XFEL facility (PAL XFEL). The stable electron beam is essential for the single-pass free electron laser facility. The beam stability is governed by an accelerating RF field, of which fluctuation is mainly caused by the modulation of klystron voltage pulses. Therefore, it is directly determined by the charging stability of a modulator that uses an inverter charging system. The stable charging power supply can be realized by a stable probing and correct manipulating of a charging signal, a fine control of charging current, low noise environment, etc. This paper shows the detail analysis of the stability dependency of a klystron-modulator on the related parameters.  
THPMA076 Development of the Klystron Modulator using a High-voltage Inverter Power Supply 743
 
  • Y. G. Son, C. W. Chung, D. E. Kim, S. J. Kwon, J.-S. Oh
    PAL, Pohang, Kyungbuk
 
  The existing klystron modulator in the Linac use a 60 Hz high voltage power supply and adopt traditional L-C resonant charging scheme with De-Qing circuit. The stability of the output high voltage is not satisfactory especially when the AC line voltage fluctuations. If an inverter power supply is used as a HV generator, it will just meet the demands A high frequency inverter switching makes the overall system size small. The command-charging feature can guarantee the high reliability of switching function. In order to increase the stability, operating reliability and comply with the PLC (programming logic controller) and touch screen control system of PLS, an upgrading works is now in progress. This paper will discuss some inverter power supply design considerations and show the test results.