WEPMA060 Measurements using the X-Ray and Optical Diagnostic Beamlines at the Australian Synchrotron 407
 
  • G. LeBlanc, J. C. Bergstrom, M. J. Boland, R. T. Dowd, M. J. Spencer, Y. E. Tan
    ASP, Clayton, Victoria
  • D. J. Peake, R. P. Rassool
    Melbourne, Melbourne
 
  First Light has been achieved on the diagnostic beamlines at the Australian Synchrotron 3 GeV storage ring. The X-ray Diagnostic Beamline (XDB) has been used to measured the beam size, divergence and emittance, while the Optical Diagnostic Beamline (ODB) has been used the measure the bunch length and turn-by-turn stability. Both beamlines receive dipole radiation from a bend magnet and provide continuous diagnostic data to the control room. The beamlines compliment each other with the ODB providing mainly longitudinal (temporal) information, while the XDB measures predominantly transverse (spatial) information. A brief description is given of the equipment on each beamline and the commissioning results are presented.