Author: Maschmann, W.
Paper Title Page
MOP029 Cryo-Losses Measurements of the XFEL Prototype and Pre-Series Cryomodules 162
 
  • S. Barbanotti, J. Eschke, K. Jensch, W. Maschmann, O. Sawlanski
    DESY, Hamburg, Germany
  • W. Gaj, L.M. Kolwicz-Chodak, W. Maciocha
    IFJ-PAN, Kraków, Poland
  • X. Wang
    ESS, Lund, Sweden
 
  Cryo-losses measurements of the XFEL prototype and pre-series cryomodules are here presented and compared with the XFEL requirements. Cryo-losses at the 4.5 K, 80 K and 2K temperatures are calculated during the test period at CMTB (CryoModule Test Bench) at DESY to qualify the cryomodules before installation. This paper summarizes the test procedure for the different circuits (2K, 4.5K, 80K) and in different load conditions: static losses, losses due to the magnet and dynamic losses due to the RF power sent to the cavities at different MV/m levels.  
 
MOP031 Quality Control of the Vessel and Cold Mass Production for the 1.3 GHz XFEL Cryomodules 168
 
  • S. Barbanotti, H. Hintz, K. Jensch, W. Maschmann
    DESY, Hamburg, Germany
 
  The industrial production of one hundred cold masses and vacuum vessels for the 1.3 GHz XFEL cryomodules is now fully in operation. Quality checks at the companies and controls at DESY assure the quality level required for the cryomodule assembly. Verification of the main production steps, non-destructive tests, dimensional controls are performed by DESY personnel before accepting the components. This paper resumes the quality control strategy and the results for the first components produced by the companies.