Author: Grolet, D.
Paper Title Page
MOP010 Spiral2 Cryomodules B Tests Results 95
 
  • G. Olry, F. Chatelet, C. Commeaux, N. Gandolfo, D. Grolet, C. Joly, J. Lesrel, D. Longuevergne, R. Martret, G. Michel, L. Renard, A. Stephen, P. Szott
    IPN, Orsay, France
  • P.-E. Bernaudin, R. Beunard, R. Ferdinand, A. Lefevre
    GANIL, Caen, France
  • Y. Gómez Martínez
    LPSC, Grenoble Cedex, France
 
  Assembly and tests of the SPIRAL2 superconducting linac's cryomodules at CEA/Saclay and IPN/Orsay have now reached cruising speed after having faced a series of problems, among them contamination. 19 cryomodules are composing the whole Linac and IPN Orsay is in charge of the 7 cryomodules B, housing two 88MHz, beta 0.12 Quarter-Wave Resonators. Two cryomodules have been successfully assembled and tested up to the nominal gradient of 6.5 MV/m for all cavities with also total cryogenic losses under specifications. One of them is fully qualified and has been already delivered to GANIL. The second one showed misalignment on one cavity which could lead to partial disassembly. This paper will present the results of those cryomodules tests as well as the status of the remaining ones.  
 
MOP075
A X-rays Shielded Facility Dedicated to Cryogenic RF Tests of Fully Dressed Spoke Cavities in the Cryomodule CM0 at IPN Orsay  
 
  • M. Fouaidy, P. Duchesne, N. Gandolfo, D. Grolet, C. Joly, G. Olry, M. Pierens, V. Poux, D. Reynet
    IPN, Orsay, France
  • C.C. Motta
    USP, São Paulo, Brazil
 
  A bulk Nb superconducting β=0.3 Triple-Spoke (T-Spoke) cavity operating at 352 MHz, was designed at IPN and fabricated thanks to EURISOL project financial support. The cavity will be tested in November 2013 at a new X-rays shielded facility dedicated to cryogenic tests of fully dressed (LHe tank, Magnetic Shields, Fast Active Cold Piezoelectric Tuning System (FACPTS), RF Power coupler) Spoke cavities in the horizontal cryomodule CM0. The CW RF power and cryogenic power @T=2K are 80kW and 120W respectively. Four vertical cold RF tests were performed in a vertical cryostat and the data are reported. All components (cold box, cryogenic lines, He gas heater, RF power system with 2 RF power couplers, LHe bath pumps) were delivered and successfully tested. The cryogenic circuit in CM0 was finished and we successfully mounted the fully dressed T-Spoke cavity. A R.T tuning system was used for static and dynamic mechanical measurements on Single (S-Spoke) and T-Spoke cavities. Mechanical stiffness, transfer function, vibrations, Lorentz detuning were investigated using the FACPTS. Field profile in S-Spoke and T-Spoke cavities were performed using a motorized field perturbation stand.