Author: Gnidzinska, K.     [Gnidzińska, K.]
Paper Title Page
THP087 LLRF Tests of XFEL Cryomodules at AMTF: First Experimental Results 1132
 
  • J. Branlard, V. Ayvazyan, M.K. Grecki, H. Schlarb, Ch. Schmidt
    DESY, Hamburg, Germany
  • W. Cichalewski, K. Gnidzińska, A. Piotrowski, K.P. Przygoda
    TUL-DMCS, Łódź, Poland
  • W. Jałmużna
    Embedded Integrated Control Systems GmbH, Hamburg, Germany
 
  In preparation for the series production of cryomodules for the European X-ray Free Electron Laser (XFEL), three pre-series cryomodules and several prototypes have been produced and tested at the Cryomodule Test Bench (CMTB) and at the Accelerating Module Test Facility (AMTF) in DESY. Among the numerous tests performed on the modules, the low-level radio frequency (LLRF) tests aim at characterizing the performance of the modules from an RF controls perspective. These integration tests must take into account cavity tuners, cavity motorized couplers, quench gradients, microphonics, piezo control and the overall gradient performance of the cryomodule under test. In this paper, the LLRF-specific tests are summarized and the first experimental results obtained at CMTB and AMTF are presented.