Author: Xu, Y.
Paper Title Page
WEPH32 Measurement of Key Parameters for EAST Neutral Beam Injector 87
 
  • Y. Xu, C.D. Hu, L.Z. Liang, S. Liu, Z.M. Liu, P. Sheng, Y.H. Xie
    ASIPP, Hefei, People's Republic of China
 
  Funding: Supported by the National Magnetic Confinement Fusion Science Program of China (2013GB101000).
Neutral beam injection is recognized as one of the most effective means of plasma heating. The target values of EAST Neutral beam injector (NBI) are beam energy 50-80kev, injection beam total power 2-4 MW, beam pulse width 10-100s. The beam power will deposit on the beam collimator due to the beam divergence and it will cause heat damage to heat load components, or even destroy the entire NBI system. In order to decrease the risk, the key parameters of NBI, such as divergence angle, beam power density distribution, neutralizing efficiency, the beam power deposited on heat load components, should be assessed. In this article, the calculation principles and experimental results are given. The results direct the operation parameter optimization of EAST NBI and lay a solid foundation for realization of plasma heating for EAST.