A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Xing, J.S.

Paper Title Page
MO6RFP022 The Design and Test of Plug-In Cryopumps 399
 
  • G.F. Pan, Z.G. Li, J.C. Qin, J.S. Xing, S.P. Zhang, T.J. Zhang
    CIAE, Beijing
  • I. Sekachev
    TRIUMF, Vancouver
 
 

The design and cryo-test system of a plug-in cryopump used in CYCIAE-100 is introduced. The plug-in cryopump consists of two cryopanels, a baffle, a half-opened shield, and two GM refrigerators (CGR411, CVI) which power is 83W/80K at the first stage and 7.5W/20K at the second stage, its designed pumping speed is 15000L/s. Cryo-test system of plug-in cryopump employs the flux method to test pumping speed, cool-down time, ultimate pressure, temperature distribution on cryopanel and capacity at the pressure of 10-6Pa to 1Pa. The heat load calculation of cryopanel and shield including baffle is conducted in succession. In the end a comparison between design parameters and test results is drawn.