Paper | Title | Page |
---|---|---|
MO6RFP065 | Simulations of Mode Separated RF Photo Cathode Gun | 515 |
|
||
At Accelerator Test Facility (ATF), we have developed and successfully used RF Photocathode gun as the source of electrons. We have also used a similar gun in the Laser Undulator Compact X-ray source facility (LUCX), KEK (High Energy Accelerator Research Organization) for performing experiments to generate X-rays by inverse Compton scattering. Both the existing guns have mode separation of 4 MHz. We designed a new RF Gun with high mode separation of around 9 MHz and high Q value to achieve a low emittance beam of good quality. We are also modifying the power delivery scheme to the accelerator at LUCX to achieve the acceleration of 200 nC in 100 bunches with low emittance. This will help to increase the intensity of X-rays by the inverse Compton scattering. |
||
TU6PFP027 | Improvement of Compact Pico-Second and Nano-Second Pulse Radiolysis Systems at Waseda University | 1345 |
|
||
A pulse radiolysis method is very useful in clarifying primary processes of radiation chemistry. At Waseda University, compact pico-second and nano-second pulse radiolysis systems have been developing. A pico-second system is based on pump-probe method. IR and UV pico-second laser pulses are generated from Nd:YLF mode-locked laser and used for generating of white light continuum as analyzing light and irradiating to photo-cathode RF gun, respectively. Recently, we have installed a new photo-cathode RF gun with Cs-Te cathode which has high quantum efficiency, so we have succeeded in improving optical density and S/N ratio of our pulse radiolysis system. We are now developing a new nano-second system which can get time profile with only one-shot and follow up wider time region than pico-second system. In the past, this system has been used He-Ne laser as analyzing light, but it can measure only 633nm. Instead of He-Ne laser, this system adopts Xe flush lamp which has broad spectrum as analyzing light. As system evaluation experiments, we tried to get time profile of some species. In this conference, present status and future plans of our pulse radiolysis systems will be reported. |
||
WE3GRC04 | 3-Dimensional Beam Profile Monitor Based on a Pulse Storage in an Optical Cavity for Multi-Bunch Electron Beam | 1925 |
|
||
Funding: Work supported by a Grant-In-Aid for Creative Scientific Research of JSPS (KAKENHI 17GS0210) and a Grant-In-Aid for JSPS Fellows (19-5789) We have been developing a pulsed-laser storage technique in a super-cavity for compact X-ray sources. The pulsed-laser super-cavity enables to make high peak power and small waist laser at the collision point with the electron beam. Recently, using 357 MHz mode-locked Nd:VAN laser pulses which stacked in a super-cavity scattered off a multi-bunch electron beam, we obtained multi-pulse X-rays through laser-Compton scattering. Detecting an X-ray pulse-by-pulse using a high-speed detector makes it possible to measure the 3-dimensional beam size with bunch-by-bunch scanning the laserwire target position and pulse timing. This technique provides not only the non-destructive beam profile monitoring but also the measuring of bunch length and/or bunch spacing shifting. In our multi-bunch electron linac, the bunch spacing narrowing due to the electron velocity difference in the train at the output of rf-gun cavity was observed. The principle of the 3-dimensional laserwire monitor and the experimental results of multi-bunch electron beam measurements will be presented at the conference. |
||
|
||
MO6RFP102 | Present Status of a Multi-Bunch Electron Beam Linac Based on Cs-Te Photo-Cathode RF-Gun at Waseda University | 608 |
|
||
At Waseda University, we have been developing a high quality electron source based on photo-cathode rf-gun and its application experiments. To produce a high current electron beam, we installed a Cs-Te cathode which has higher quantum efficiency and improved the structure of the rf cavity. By adopting a Cs-Te cathode, it is expected that the production of the higher charged single bunch electron beam with a low emittance can be achieved. Moreover, the generation of high quality multi-bunch electron beam is also expected to be possible due to the high quantum efficiency of Cs-Te. For understanding of a Cs-Te cathode and higher quantum efficiency operation, we have performed the fundamental studies by single bunch beam. On the other hand, we have also developed a multi-pulse UV laser for generating the multi-bunch electron beam. Our laser system is composed by all-solid-state Nd:YLF for the stable operation, and the specification of this laser is expected to generate a 100bunch/train with the bunch charge of 800pC/bunch. In this conference, the experimental results of Cs-Te and new laser system and the recent progress of multi-bunch electron beam generation will be reported. |