A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Wang, J.G.

Paper Title Page
TH5RFP056 Beam Diagnostics at IR Wavelengths at NSRL 3582
 
  • A. Bocci, A. Drago, A. Marcelli
    INFN/LNF, Frascati (Roma)
  • C. Li, Z. Qi, B. Sun, B.Y. Wang, J.G. Wang, Z.Y. Wu
    USTC/NSRL, Hefei, Anhui
  • J.P. Piotrowski
    VIGO System S.A., Ozarow Maz.
 
 

Real time diagnostics is a fundamental tool for accelerator physics, particularly important to improve performances of existing synchrotron radiation sources, colliders and a key issue for 4th generation sources and FELs. We report the first measurements in the time and frequency domain performed at Hefei Light Source (HLS), the SR facility of the National Synchrotron Radiation Laboratory (NSRL), of the longitudinal bunch lengths. A fast uncooled HgCdTe photodiode optimized in the mid-IR range has been used to record at the IR port the length of the e- bunches. IR devices are compact and low cost detectors suitable for a bunch-by-bunch longitudinal diagnostics. The data are useful to investigate longitudinal oscillations and characterize the bunch length. The IR signal has been used to measure the synchrotron oscillation frequency, its harmonics in the multi-bunch mode and the bunch lengths in multi-bunch mode at different beam currents. For the first time, simultaneously, data have been collected at visible wavelengths using a fast photodiode at the diagnostics beamline of HLS. A comparison between IR data and diagnostics realized in the visible will be presented and discussed.

 
TH6REP060 Beam Parameters Measurement with a Streak Camera in HLS 4087
 
  • J.G. Wang, B. Sun, B.Y. Wang, H. Xu
    USTC/NSRL, Hefei, Anhui
 
 

In HLS streak camera system has been built. The system is used to measure some parameters of bunch like bunch length, longitudinal bunch profile and synchrotron frequency and so on, as it may report a direct derivation of fundamental machine characteristics. The system mainly consists of the synchrotron light extracting optics setup, the OPTOSCOPE streak camera and PC with a frame grabber interface card. The light extracting optics setup is used to extract synchrotron light at the bending magnet and the setup consists of the light extracting path and the optics imaging system. The streak camera realizes the functions of acquiring light and imaging. PC with a frame grabber interface card and ARP-Optoscope software package is used to monitor the light in real-time, acquire the image of light and analyze the data. The streak camera system operates with either synchroscan sweep mode or dual time base sweep mode. At present, some results are given, which include the bunch lengthening, the longitudinal bunch profile and the synchrotron frequency. These results are compared with the results acquired by using oscilloscope.

 
TH6REP061 Design of Beam Measurement System for High Brightness Injector in HLS 4090
 
  • X.H. Wang, J. Fang, P. Lu, Q. Luo, B. Sun, J.G. Wang
    USTC/NSRL, Hefei, Anhui
 
 

A high brightness injector has been developing in HLS (Hefei Light Source), and the design of beam parameter measurement system is presented in this paper. The whole system will measure beam position, beam current, emittance of beam, bunch length, beam energy and energy spread. For the beam position, we have designed three types of BPMs: stripline BPM, with the resolution of 20 μm; cavity BPM, with the resolution of 10 μm, and resonant stripline BPM*. The beam position processor Libera will be used. The beam current will measured using the ICT and FCT. When going out of the gun, the energy of the beam is about 4MeV – 5MeV, and the emittance of the beam is charge-dominated, so we use a set of slits with the width of 90 μm to split the beam to beamlets. The bunch length is measured using OTR and streak camera. Before entering the bending magnet, the beam will go pass a very narrow slit, with the width of 90 μm, and the resolution of energy spread will be improved.


*M.Dehler, “Resonant Strip line BPM for Ultra Low Current Measurements”, Proceedings of DIPAC 2005, Lyon, France, p.286-288