Uesaka, M.

Paper Title Page
MO6RFP094 Commissioning of Na2KSb Photocathode RF Gun in S-Band Linac at the University of Tokyo 587
 
  • K. Miyoshi, Y. Muroya, A. Sakumi, T. Ueda, M. Uesaka
    The University of Tokyo, Nuclear Professional School, Ibaraki-ken
  • K. Kambe
    UTNL, Ibaraki
 
 

Multi-Alkali photocathode has the good possibility as a electron source which has high quantum efficiency and low workfunction. However the surface of the cathode is sensitive over the electric field of 100[MV/m] in a RFgun, the amount of dark current is not negligible. In order to reduce such a dark current, we consider the valance of the electric field between half-cell and full-cell of BNL-IV RF gun by numerical simulation using GPT code. In this work we will show that high quality electron beam can be transported on the condition that appled electric field in half and full cell is about 50[MV/m] and 150[MV/m] respectively.

 
TU6PFP003 Application of Portable 950 keV X-Band Linac X-Ray Source to Condition Based Maintenance for Pump-Impeller 1293
 
  • T. Yamamoto, T. Natsui
    UTNL, Ibaraki
  • E. Hashimoto, S. Hirai, K. Lee, M. Uesaka
    The University of Tokyo, Nuclear Professional School, Ibaraki-ken
  • J. Kusano, N. Nakamura, M. Yamamoto
    A, Kawasaki, Kanagawa
  • E. Tanabe
    AET Japan, Inc., Kawasaki-City
 
 

We are developing X-ray nondestructive testing (NDT) system using with portable X-band linac. This system uses 9.4 GHz X-band linac and 250 kW magnetron. Our system energy is 950 keV for Japanese regulation. Therefore we can use it on-site using local radiation protection. We measured electron beam and X-ray. We have started X-ray imaging test. We will use this system for condition based maintenance of pump-impeller at nuclear plants. The linac based X-ray source can generate pulsed X-ray. Therefore we can get still images without stopping rotation when x-ray repetition rate synchronizes impeller's rotaion rate. We are successfull in proof of principle using a simple fan and a synchronized circuit. We prepare real-time imaging for conventional pump. In this paper, we will explain the detail of this system and expermental results.

 
TU6PFP016 Pinpoint keV X-Ray Imaging for X-Ray Drug Delivery System 1328
 
  • M. Uesaka
    The University of Tokyo, Nuclear Professional School, Ibaraki-ken
  • R. Kuroda, K. Yamada
    AIST, Tsukuba, Ibaraki
  • K. Mizuno, A. Mori, T. Natsui, H. Taguchi, J.D. Trono
    University of Tokyo, Tokyo
  • N. Yusa
    Tohoku University, Graduate School of Engineering, Sendai
 
 

In X-ray Drug Delivery System, anticancer drugs containing Pt, such as cisplatin and dachplatin, and Au colloid contrast agent are surrounded by polymers (micelle, PEG (polyethylene glycol), etc.).Ttheir sizes are controlled to be 20-100 nm. Since holes of capillary to organ are as large as 100 nm in only cancer, those large particles can be accumulated in cancer effectively. That is called as EPR (Extended Penetration and Retention effect). We have observed the distribution of Pt of dachplatin-micelle in cancer of mouse’s pancreas by X-ray fluorescence analysis using 10 μm pinpoint 15 keV X-ray by SPring8. Further, in-vitro- and in-vivo-experiments of Au colloid PEG are under way. It is expected to be used as contrast agent for dynamic tracking treatment for moving cancer. Imaging properties for polychromatic X-rays from X-ray tube and monochromatic Compton source are numerically analyzed and discussed. We continue to analyze radiation enhancement by Auger electrons and successive characteristic X-rays and its toxic effect to cancer.

 
TH6REP045 Developments of 3-D EO Bunch Shape Monitor for XFEL/SPring-8 4054
 
  • A. Maekawa, M. Uesaka
    The University of Tokyo, Nuclear Professional School, Ibaraki-ken
  • H. Tomizawa
    JASRI/SPring-8, Hyogo-ken
 
 

In XFEL/SPring-8, it requires ultra high-brightness electron bunches with ultralow slice emittance and bunch duration of 30 fs (FWHM) in a lasing part. In order to measure such bunches, we are developing a single-shot, non-destructive, real-time 3-D bunch shape monitor based on EO sampling with a manner of spectral decoding. It consists of a radially polarized probe laser and 8 EO-crystals, which surround a beam axis azimuthally and their crystal-axes are radially distributed as well as Coulomb fields of electron bunches. The probe laser has a linear-chirped broad bandwidth (> 400 nm at 800 nm of a central wavelength) for higher temporal resolution, and a hollow shape to avoid interacting with electron bunches. As an EO crystal, we investigate the feasibility of an organic crystal such as a DAST for 20-fs temporal response. This monitor can measure not only longitudinal but also transverse charge distribution at the same time. These real-time 3-D bunch shape measurements are very important to optimize electron bunches for XFEL operation. We present the scheme of this monitor with its estimation in detail and report the developing status for probe laser and organic-EO-crystals.

 
FR5RFP026 All-Optical Compton Gamma-Ray Source 4589
 
  • K. Koyama, A. Yamazaki
    UTNL, Ibaraki
  • T. Hosokai
    RLNR, Tokyo
  • A. Maekawa, M. Uesaka
    The University of Tokyo, Nuclear Professional School, Ibaraki-ken
  • M. Miyashita
    SUT, Noda-shi, Chiba
 
 

An all-optical inverse Compton gamma-ray source is enable us to make a tabletop monochromatic gamma-ray source that might be applied to measure an amount of nuclear material, etc. An intense laser pulse excites a very nonlinear plasma wave and accelerate electron bunch up to several-hundreds MeV within a length of a few millimeters. The key to success is stabilization of the laser-plasma accelerators. We are developing the artificial injection technique of initial electrons in to the plasma wave and guiding of the intense laser pulse by the preformed plasma channel.