TU5RFP018 Orbit Improvements at the Canadian Light Source 1129
 
  • T. Summers, D. Chabot, L.O. Dallin, M.J. Sigrist
    CLS, Saskatoon, Saskatchewan
 
 

Upgrades to the orbit control system at the Canadian Light Source (CLS) have resulted in increased beam stability and reproducibility. These upgrades include improving position information from the beam position monitors (BPMs) by modifying the data acquisition algorithm and switching to a real-time operating system. Beam motion has been reduced to an RMS deviation of less than 1 micron in both planes. Limiting the maximum corrector step has allowed the use of all singular values when inverting the BPM response matrix, resulting in much better orbit reproducibility. As well, improved lookup tables have been developed to compensate for the effects of changing undulator gaps and polarizations. Presently, work is underway to develop fast orbit correction with rates up to 100 Hz. Fast orbit correction will further reduce the residual perturbations caused by undulator activity and will allow fast ramping of superconducting wigglers.