A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Sugai, I.

Paper Title Page
TU6RFP055 Measurements of the Temperature on Carbon Stripper Foils by Pulsed 650keV H- Ion Beams 1674
 
  • A. Takagi, Y. Irie, I. Sugai, Y. Takeda
    KEK, Ibaraki
 
 

Thick carbon foils (>300 ug/cm2)has been used for stripping of H- ion beam at the 3GeV Rapid Cycling Synchrotron (3GeV-RCS) of J-PARC, where foils with long lifetime against high temperature >1800 °K are strongly required for efficient accelerator operations. The key parameter to the foil lifetime is foil temperature attained during irradiation. We have recently developed a new irradiation system for lifetime measurement using the KEK 650 keV Cockcroft-Walton accelerator with high current pulsed and dc H- beam, which can simulate the high-energy depositions upon foils in the RCS. During irradiation tests by this system, the temperature of foil is measured by a thermometer in a dc mode, and by using a photo-transistor in a pulsed mode. This paper describes the pulsed measurements with 5-10 mApeak, 0.1-0.5 msec duration and 25 Hz repetition.