Paper | Title | Page |
---|---|---|
MO6RFP021 | TRIUMF Cyclotron Vacuum System Upgrade and Operational Experience | 396 |
|
||
The replacement of the 30-year-old Philips cryogenerator with a modern LINDE-1630 helium refrigerator is an important component of TRIUMF’s ongoing 500 MeV cyclotron refurbishing program. Two 10.7 m long cryopanels are cooled with liquid helium rather than with 17 K helium gas, as was the case with the cryogenerator. This has increased the pumping speed and, respectively, improved the vacuum in the approximately 100 m3 cyclotron tank. Additionally, the thermal shield, previously cooled with helium gas, is now cooled with liquid nitrogen. These changes have resulted in increased reliability of the cyclotron vacuum system and, consequently, longer operation periods without maintenance. The new refrigeration unit was commissioned in September 2007. The results from over one year of operational experience are discussed. Also, data on hydrogen cryopumping is presented. |