A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Saveliev, Y.M.

Paper Title Page
TU5RFP083 Progress on the Commissioning of ALICE, the Energy Recovery Linac-Based Light Source at Daresbury Laboratory 1281
 
  • S.L. Smith, R. Bate, C.D. Beard, M.A. Bowler, R.K. Buckley, S.R. Buckley, J.A. Clarke, P.A. Corlett, M. Dufau, D.J. Dunning, B.D. Fell, P. Goudket, A.R. Goulden, S.A. Griffiths, J.D. Herbert, C. Hill, F. Jackson, S.P. Jamison, J.K. Jones, L.B. Jones, A. Kalinin, N. Marks, P.A. McIntosh, J.W. McKenzie, K.J. Middleman, B.L. Militsyn, A.J. Moss, B.D. Muratori, J.F. Orrett, S.M. Pattalwar, P.J. Phillips, M.W. Poole, Y.M. Saveliev, D.J. Scott, B.J.A. Shepherd, R.J. Smith, N. Thompson, B. Todd, T.M. Weston, A.E. Wheelhouse, P.H. Williams
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
  • J.R. Alexander, P. Atkinson, N. Bliss, I. Burrows, G. Cox, P.A.D. Dickenson, A. Gallagher, K.D. Gleave, J.P. Hindley, B.G. Martlew, I.D. Mullacrane, A. Oates, P.D. Quinn, D.G. Stokes, J. Strachan, P.J. Warburton, C.J. White
    STFC/DL, Daresbury, Warrington, Cheshire
  • W.R. Flavell, E.A. Seddon
    UMAN, Manchester
  • F.G. Gabriel
    FZD, Dresden
  • C. Gerth
    DESY, Hamburg
  • F.E. Hannon, C. Hernandez-Garcia, K. Jordan, G. Neil
    JLAB, Newport News, Virginia
  • K. Harada
    KEK, Ibaraki
  • P. Harrison, D.J. Holder, G.M. Holder, P. Weightman
    The University of Liverpool, Liverpool
  • S.F. Hill, G. Priebe, R.V. Rotheroe, M. Surman
    STFC/DL/SRD, Daresbury, Warrington, Cheshire
  • G.J. Hirst, P.G. Huggard
    STFC/RAL, Chilton, Didcot, Oxon
  • P. vom Stein
    ACCEL, Bergisch Gladbach
 
 

ALICE (Accelerators and Lasers in Combined Experiments) is a 35 MeV energy recovery linac based light source. ALICE is being developed as an experimental test-bed for a broad suite of science and technology activities that make use of electron acceleration and ultra-short pulse laser techniques. This paper reports the progress made in accelerator commissioning and includes the results of measurement made on the commissioning beam. The steps taken to prepare the beam for short pulse operation as a driver for a Compton Back Scattered source and in preparation for the commissioning of the free electron laser are reported.

 
FR5PFP027 Extended ALICE Injector 4363
 
  • J.W. McKenzie, B.D. Muratori, Y.M. Saveliev
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
 
 

Results of designing of the extended ALICE injector with the aim to include a special dedicated diagnostic line are presented. The purpose of the diagnostic line is to characterise the low energy beam, before it enters the booster, as much as possible. A key component of the ALICE is the high brightness injector. The ALICE injector consists of a DC photocathode gun generating ~ 80 pC electron bunches at 350 keV. These bunches are then matched into a booster cavity which accelerates them to an energy of 8.35 MeV. In order to do this, three solenoids and a single-cell buncher cavity are used, together with the off-crest of the first booster cavity where the beam is still far from being relativistic. The performance of the injector has been studied using the particle tracking code ASTRA.

 
FR5REP109 EMMA Commissioning 5029
 
  • B.D. Muratori, J.K. Jones, Y.M. Saveliev, S.L. Smith, S.I. Tzenov
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
  • J.S. Berg
    BNL, Upton, Long Island, New York
  • C. Johnstone
    Fermilab, Batavia
  • S.R. Koscielniak
    TRIUMF, Vancouver
 
 

EMMA (Electron Machine with Many Applications) is a prototype non-scaling electron FFAG to be hosted at Daresbury Laboratory. NS-FFAGs related to EMMA have an unprecedented potential for medical accelerators for carbon and proton hadron therapy. It also represents a possible active element for an ADSR (Accelerator Driven Sub-critical Reactor). This paper summarises the commissioning plans for this machine together with the major steps and experiments involved along the way. A description of how the 10 to 20 MeV beam is achieved within ALICE is also given, as well as extraction from the EMMA ring to the diagnostics line and then dump.