A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Rossmanith, R.

Paper Title Page
WE5RFP086 New Materials and Designs for Superconductive Insertion Devices 2471
 
  • P. Peiffer, T. Baumbach, A. Bernhard, G. Fuchert, D. Wollmann
    KIT, Karlsruhe
  • R. Maccaferri, Y. Papaphilippou
    CERN, Geneva
  • R. Rossmanith
    FZ Karlsruhe, Karlsruhe
 
 

NbTi wires are relatively easy to handle and are therefore up to now the preferred material for superconductive insertion devices. Yet other materials, like Nb3Sn, MgB2 or high temperature superconductors, are less sensitive to beam heat load and/or are able to produce higher magnetic fields. In this paper the different superconducting materials and their advantages and challenges are discussed. Additionally this paper describes new designs for special insertion devices like damping wigglers and undulators for laser wakefield accelerators.

 
WE5RFP064 A New Superconducting Undulator for the ANKA Synchrotron Light Source 2410
 
  • C. Boffo, M. Borlein, W. Walter
    BNG, Würzburg
  • T. Baumbach, A. Bernhard
    KIT, Karlsruhe
  • S. Casalbuoni, A.W. Grau, M. Hagelstein, R. Rossmanith
    FZK, Karlsruhe
  • E.M. Mashkina
    University Erlangen-Nuernberg, Erlangen
 
 

Superconducting insertion devices (IDs) are very attractive for synchrotron light sources since they allow increasing the flux and/or the photon energy with respect to permanent magnet IDs. Babcock Noell GmbH (BNG) is completing the fabrication of a 1.5 m long unit for ANKA at FZK. The period length of the device is 15 mm for a total of 100.5 full periods plus an additional matching period at each end. The key specifications of the system are: a K value higher than 2 and the capability of withstanding a 4 W beam heat load and a phase error of 3.5 degrees. In addition, during the injection phase of the machine, the nominal gap of 5 mm can be increased up to 25 mm. The magnets have been tested with liquid helium in a vertical dewar and are now being installed in the cryostat. This paper describes the technical design concepts of the device and the status of the assembly process.

 
WE5RFP084 Spectral Characterisation of the ANKA-SCU Radiation 2465
 
  • A. Bernhard, T. Baumbach, F. Burkart, S. Ehlers, G. Fuchert, P. Peiffer, M. Wolf, D. Wollmann
    KIT, Karlsruhe
  • B. Kostka
    University of Erlangen-Nürnberg, Physikalisches Institut II, Erlangen
  • R. Rossmanith
    FZK, Karlsruhe
 
 

The ANKA superconductive undulator (SCU14) is continously operated since 2005. The main objetive of this operation was to investigate the interactions between the undulator and the stored electron beam and to characterise the undulator radiation. The characterisation of the undulator radiation was done with a short test beamline designed for spacially and spectrally resolved measurements of the undulator radiation intensity. This contribution summarises the results of these measurements. The spectra are cross-correlated with the magnetic field measurements carried out earlier.

 
WE5RFP085 Magnetic Field Transients in Superconductive Undulators 2468
 
  • S. Ehlers, T. Baumbach, G. Fuchert, P. Peiffer, D. Wollmann
    KIT, Karlsruhe
  • A. Bernhard, R. Rossmanith
    FZK, Karlsruhe
  • D. Schoerling
    IMFD, Freiberg
 
 

The next step towards introducing superconductive undulators as the new generation of insertion devices is to understand the impact of dynamic effects in the superconducting coils on the accelerator beam. These effects are seen as a temporal drift of the beam orbit, originating from transients of the magnetic field. The first systematic time resolved measurements of such drifts have been performed ANKA. Orbit displacement during several different ramping cycles, for different ramp rates and relaxation times, has been investigated. This contribution summarises the results of the measurements. The persistent current effects in the superconducting wires, as well as eddy currents in the yoke are discussed as possible sources for the transients.

 
WE5RFP087 Experimental Demonstration of the Induction Shimming Concept in Superconductive Undulators 2474
 
  • D. Wollmann, T. Baumbach, A. Bernhard, P. Peiffer
    KIT, Karlsruhe
  • A.W. Grau, R. Rossmanith
    FZK, Karlsruhe
  • E.M. Mashkina
    University Erlangen-Nuernberg, Erlangen
 
 

Recently a new concept for automatically reducing magnetic field errors in superconductive undulators was proposed. According to this proposal the field errors are compensated by an array of coupled high temperature superconductor loops attached to the surface of the superconductive undulator. The field errors induce currents in the coupled type II-superconducting loops and, as a result, the magnetic field generated by these currents minimizes the field errors. In this paper the results of a first successful experimental test of this concept are described.

 
TU5RFP028 TBONE: Ultra-Fast High-Power Coherent THz to Mid-IR Radiation Facility 1156
 
  • A.-S. Müller, T. Baumbach, S. Casalbuoni, B. Gasharova, M. Hagelstein, E. Huttel, Y.-L. Mathis, D.A. Moss, A. Plech, R. Rossmanith
    FZK, Karlsruhe
  • E. Bründermann, M. Havenith
    Ruhr-Universität Bochum, Bochum
  • S. Hillenbrand, K.G. Sonnad
    KIT, Karlsruhe
 
 

A linac based coherent radiation source in the THz to mid-IR range is proposed. The TBONE machine will deliver pulses of radiation as short as a few fs in the frequency range from 0.1 to 150 THz with up to MW peak power. This combination of parameters will open up unprecedented opportunities in THz and infrared applications, such as e.g. microscopy or spectroscopy. This paper presents the main parameters and design considerations. Special emphasis is put on the study of suitable bunch compression and beam transport schemes.

 
WE5RFP068 Design, Development and Testing of Diagnostic Systems for Superconducting Undulators 2417
 
  • M. Hagelstein, T. Baumbach, S. Casalbuoni, A.W. Grau, B. Kostka, R. Rossmanith, D. Saez de Jauregui
    FZK, Karlsruhe
  • A. Bernhard, D. Wollmann
    KIT, Karlsruhe
  • J. Chavanne, P. Elleaume
    ESRF, Grenoble
  • B. Diviacco
    ELETTRA, Basovizza
  • E.M. Mashkina
    University Erlangen-Nurnberg, Institute of Condensed Matter Physics, Erlangen
  • E.J. Wallén
    MAX-lab, Lund
 
 

Within the framework of a joint research activity of the European project IA-SFS (RII3-CT2004-506008) four synchrotron facilities have jointly developed diagnostic systems for superconducting undulators. Four work packages have been successfully completed: Design and construction of a test cryostat for field measurements; design and construction of a mock-up coil; field measurement and field error compensation; diagnostics and measurement of the spectrum of low energy electrons responsible for beam heat load in a superconducting undulator. The development advanced the knowledge of magnetic field error compensation considerably and might be of help in understanding the different beam heat load sources. Based on the development a second generation planar superconducting undulator with 15 mm period length for the synchrotron light source ANKA has been specified and procured.