TU3GRI03 | NSLS-II Beam Diagnostics Overview | 746 |
|
||
A new 3rd generation light source (NSLS-II project) is in the early stage of construction at Brookhaven National Laboratory. The NSLS-II facility will provide ultra high brightness and flux with exceptional beam stability. It presents several challenges in the diagnostics and instrumentation, related to the extremely small emittance. In this paper, we present an overview of all planned instrumentation systems, results from research & development activities; and then focus on other challenging aspects. |
||
|
||
TH5PFP080 | Results from a Test Fixture for Button BPM Trapped Mode Measurements | 3389 |
|
||
Three-dimensional electromagnetic simulations have suggested a variety of measures to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. |
||
TH5RFP011 | BPM Button Optimization to Minimize Distortion due to Trapped Mode Heating | 3462 |
|
||
The thermal distortion resulting from BPM button trapped mode heating is potentially problematic for achieving the high precision beam position measurement needed to provide the sub-micron beam position stability required by light source users. We present a button design that has been thermo-mechanically optimized via material selection and component geometry to minimize this thermal distortion. Detailed electromagnetic analysis of the button geometry is presented elsewhere in these proceedings. |
||
TH5RFP012 | Development of High Stability Supports for NSLS-II RF BPMs | 3465 |
|
||
The NSLS-II Light Source being built at Brookhaven National Laboratory is expected to provide submicron stability of the electron orbit in the storage ring in order to utilize fully the very small emittances and electron beam sizes. This requires high stability supports for BPM pick-up electrodes, located near insertion device source. Description of the efforts for development of supports including carbon tubes and invar rods is presented. |
||
TH5RFP014 | Evaluation of Heat Dissipation in the BPM Buttons | 3471 |
|
||
Funding: Work supported by U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract DE-AC02-98CH10886. With growth of circulating current in the storage rings the heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the BPM design for the NSLS-II project. |
||
TH5RFP015 | Preliminary Design of Pinhole Camera for NSLS-II Project | 3473 |
|
||
Funding: Work supported by U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract DE-AC02-98CH10886. The NSLS-II Light Source being built at Brookhaven National Laboratory is expected to provide very small emittances and electron beam sizes. High resolution imaging systems are required in order to provide robust measurements. The pinhole cameras will utilize 5-fold magnification with a pinhole placed inside a crotch absorber. The pinhole is protected from high power synchrotron radiation with a filter made of refractory metal. In this paper we provide resolution analyses, heat load calculations, and optimization of NSLS-II pinhole cameras including beamline design. |
||
TH5RFP016 | Comparison of RF BPM Receivers for NSLS-II Project | 3476 |
|
||
Funding: Work supported by U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contracts DE-AC02-98CH10886 and DE-AC02-06CH11357. The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies. The details of the program and preliminary results are presented. |