Paper | Title | Page |
---|---|---|
TH5RFP082 | Propagation Error Simulations Concerning the CLIC Active Prealignment | 3639 |
|
||
The CLIC components will have to be pre-aligned within a tolerance of 10 microns over a sliding window of 200m all along the linacs, before injecting the first beam. Such tolerance is about 30 times more demanding than for the existing machines as the SPS and LHC; it is a technical challenge and a key issue for the CLIC feasibility. In order to define the CLIC alignment strategy from the survey and beam dynamics point of view, simulations have been undertaken concerning the propagation error due to the measurement uncertainties of the pre-alignment systems. The uncertainties of measurement, taken as hypotheses for the simulations, are based on the data obtained on several dedicated facilities. This paper introduces the facilities and the latest results obtained, as well as the simulations performed. |