Paper | Title | Page |
---|---|---|
TH6REP012 | Low-Energy Emittance Studies with the New SNS Allison Emittance Scanner | 3974 |
|
||
Funding: *SNS is managed by UT-Battelle, LLC, under contract DE-AC05-00OR22725 for the U.S. Department of Energy. The new SNS Allison emittance scanner measures emittances of 65 kV ion beams over a range of ± 116 mrad. Its versatile control system allows for time-dependent emittance measurements synchronized by an external trigger, and therefore is suited for studying pulsed systems. After a programmable delay the system acquires a variable array of beam current measurements, each averaged over a changeable time span. The baseline of the current measurements are determined by averaging a fraction of 1 ms shortly before the start of the ion beam pulse. This paper presents the time evolution of emittance ellipses during the 1 ms H- beam pulses emerging from the SNS test LEBT, which is important for loss considerations. In addition it presents the time evolution of emittance ellipses during the 3 week active lifetime of an SNS H- source, which is an operational issue. Additional emittance data characterize the dependence on the electron-dump voltage, the extractor voltage, and the LEBT lens voltages, all of which were critical for reaching the 38 mA baseline H- beam current. Emittance data for the dependence on the beam current highlight the challenges for the SNS power upgrade. |