Paper | Title | Page |
---|---|---|
FR5PFP028 | Linear Optics Calibrations for the SSRF Storage Ring Based on COD | 4366 |
|
||
Funding: SSRF The ssrf is a 3rd generation light source under commissioning. The commissioning of the storage ring has progressed very well so far. The periodicity and symmetry of the linear optics in a real storage ring is important, however maybe be broken by various errors, such as field errors, manufactured errors. A distorted linear optics can excite stronger nonlinear resonances, which will reduce the storage ring dynamic aperture and make the storage ring suffer from low injection efficiency and short beam lifetime. Therefore, it is necessary to restore the designed periodicity or symmetry of the linear optics based on measured closed orbit distortion. The calibration procedure can be done by using LOCO (the Linear Optics from Closed Orbit). After fitting the measured response matrix by the model one, the linear optics of the storage ring is calibrated. And different operation modes have been also measured and calibrated. |