Paper | Title | Page |
---|---|---|
TH6REP054 | Calibration of Quadrupole Component of Beam Position Monitor at HLS LINAC | 4075 |
|
||
The strip-line beam position monitor can be used as a non-intercepting emittance measurement monitor. The most important part of emittance measurement is to pick up the quadrupole component. To improve the accuracy of measurement, the response of the strip-line BPM pickups will be mapped before it’s installed in the HLS LINAC. This paper introduce the calibration system of the BPM, which consists of a movable antenna and a RF signal source, simulating the beam , a BPM moving bench with its control system, and an electronics system. When the position calibration is done first, the offset between electronic center and mechanical one of the BPM and the position sensitivity are gotten. There are two methods for quadrupole component calibration: one is indirect evaluation method that estimates the sensitivity of quadrupole component by the factor of position second moment; the other is direct method by simulation of a Gaussian beam through together many Gaussian weighted grid points. The results of two methods are given and compared. The effect of antenna’s diameter upon the fitting size of simulate beam has also been analyzed. |