A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Li, H.T.

Paper Title Page
TU6RFP068 Test of the Prototype Module of PTS 1705
 
  • H.T. Li, J. Deng, S. Feng, M. Xia, W. Xie
    CAEP/IFP, Mainyang, Sichuan
 
 

Funding: Hongtao Li is with the Institute of Fluid Physics, China Academy of Engineering Physics (CAEP), Mianyang City, Sichuan, China. (Fax:86-816-2282695; e-mail: lht680526@ 21cn.com).


In order to study the physics of fast Z-pinches and research the key issues of pulse power technology, a 10MA/6MV z-pinch primary test stand (PTS) composed of 24 modules will be built in IFP. The prototype module adopted capacitive storage scheme is composed of the 6MV/300kJ Marx-generator (MG), intermediate storage capacitor (IC), laser-triggered switch (LTS), pulse forming line (PFL), water self-breakdown switch (WS), and tri-plate pulse transmission line (PTL). The measured output current of the prototype is approximate 520kA, and output voltage is approximate 2.1MV. The unique multi-stage LTS based on uniform field distribution design and multi-pin unsymmetrical WS make the prototype modules have low systemic delay jitter which is necessary for synchronization of multi-module facility. 1-δ jitter of delay of the system is less than 4ns.

 
FR2RAI01 R&D for Linear Induction Accelerator in China 4259
 
  • J. Deng, N. Chen, G. Dai, Z. Dai, B. Ding, H.T. Li, J. Li, J. Shi, H. Wang, J. Wang, M. Wang, S. Wang, L. Wen, Y. Xie, Z. Xie, K. Zhang, L. Zhang, W.W. Zhang
    CAEP/IFP, Mainyang, Sichuan
  • Y. Lin, C.-X. Tang
    TUB, Beijing
  • X.S. Liu
    CAEP/IAE, Mianyang, Sichuan
 
 

It has been three decades since the research and development of key technologies and components started at the Institute of Fluid Physics, CAEP, for the linear induction accelerator (LIA). The first LIA was built in 1989 with beam parameters of 1.5 MeV, 3 kA and pulse width of 90 ns. Later the SG-I LIA (3.3 MeV, 2 kA, 90 ns) was developed for FEL in 1991. The first Linear Induction Accelerator X-Ray Facility (LIAXF, 10 MeV, 2 kA, 90 ns, spot size about 6 mm in diameter) was built in 1993 and upgraded to 12 MeV with higher performance (LIAXFU, 12 MeV, 2.5 kA, 90 ns, spot size about 4 mm in diameter) in 1995. The Dragon-I LIA with the best quality (20 MeV, 2.5 kA, 80 ns, spot size about 1 mm in diameter) in the world was finished in 2003. The smallest LIA with double pulses separated by 300 ns (MiniLIA, 200 keV, 1 A, 80 ns) was developed in 2007 for beam physics studies.

 

slides icon

Slides