MO6PFP035 | Magnetic Measurements of the Booster Dipole Magnets for the ALBA Synchrotron | 217 |
|
||
The paper presents the magnetic measurements of the 32 long dipoles and 8 short dipoles magnet manufactured by Sigmaphi for the ALBA synchrotron booster based in Spain. An extensive set of measurements based on search coils was made by Sigmaphi to characterize the magnetic field at different currents. This paper describes the magnetic measurements results. The measurements show the maximum field integral deviation between the magnets is within ± 3.10-3 as expected. |
||
FR5REP094 | Tracking Periodic Parameters in the Measured Magnetic Field Maps of a Spiral FFAG | 4999 |
|
||
Funding: Agence Nationale de la Recherche, France, contract NT05-1_41853 A prototype of a spiral lattice FFAG magnet has been constructed in the frame of the RACCAM project*. THis magnet is subject to extensive field measurements and 3-dimensional field map measurements. The properties and qualities of the magnet are assessed directly from ray-tracing, using stepwise integration, for deriving lattice parameters as tunes, chromaticities, dynamic paertures, etc. Reporting on this is the subject of the poster. *http://lpsc.in2p3.fr/service_accelerateurs/raccam.htm |
||
FR5REP110 | Magnetic Measurements of the RACCAM Prototype FFAG Dipole | 5032 |
|
||
The paper presents the magnetic measurements of the RACCAM prototype FFAG dipole, manufactured by SIGMAPHI for the Raccam ANR Medical FFAG project. This magnet prototyping work, started early 2006, is being performed in collaboration between the IN2P3/LPSC Laboratory team and SIGMAPHI. This paper describes the magnetic measurement results and comparison with Tosca simulation. |