Grau, A.W.

Paper Title Page
MO6PFP086 Spectrum of the Low Energy Electrons Bombarding the Wall in the ANKA Storage Ring 330
 
  • D. Saez de Jauregui, S. Casalbuoni, A.W. Grau, M. Hagelstein, E.M. Mashkina
    FZK, Eggenstein
  • R. Cimino, M. Commisso
    INFN/LNF, Frascati (Roma)
  • R. Weigel
    Max-Planck Institute for Metal Research, Stuttgart
 
 

Recent investigations with the cold bore superconducting undulator installed at ANKA indicate that the main contribution to the beam heat load is caused by electron bombardment. For a quantitative understanding of the problem a cold vacuum chamber for diagnostics has been designed. Among other important parameters (heat load, pressure, etc) this device shall monitor the spectrum of the low energy electrons bombarding the wall. In this contribution we report on the measurements of the spectrum of the low energy electrons bombarding the wall of the cold vacuum chamber in a room temperature region of the ANKA storage ring performed using a in house developed retarding field analyzer (RFA). The calibration of the RFA performed at the national laboratories of Frascati is also described.

 
MO6PFP089 Test of a Short Prototype of a Superconducting Undulator for the ANKA Synchrotron Light Source 339
 
  • E.M. Mashkina, A.J. Magerl
    University Erlangen-Nurnberg, Institute of Condensed Matter Physics, Erlangen
  • C. Boffo, M. Borlein, W. Walter
    BNG, Würzburg
  • S. Casalbuoni, A.W. Grau, M. Hagelstein, D. Saez de Jauregui
    FZK, Karlsruhe
  • N. Vassiljev
    University Erlangen-Nuernberg, Institute of Condensed Matter Physics, Erlangen
 
 

A new 15 mm period, 1.5 m long planar undulator is being fabricated by Babcock Noell GmbH (BNG) for the ANKA synchrotron light source. In order to qualify the production process and to optimize both the quench protection scheme and the magnetic field correction system, a short prototype has been fabricated. The prototype has been tested in vertical configuration and liquid helium at 4.2K in the CASPER facility at ANKA. The magnetic field has been measured along the beam axis direction by Hall probes with a positioning precision of 3 μm. We report here on the field shimming scheme and the resulting performance of the coils.

 
WE5RFP064 A New Superconducting Undulator for the ANKA Synchrotron Light Source 2410
 
  • C. Boffo, M. Borlein, W. Walter
    BNG, Würzburg
  • T. Baumbach, A. Bernhard
    KIT, Karlsruhe
  • S. Casalbuoni, A.W. Grau, M. Hagelstein, R. Rossmanith
    FZK, Karlsruhe
  • E.M. Mashkina
    University Erlangen-Nuernberg, Erlangen
 
 

Superconducting insertion devices (IDs) are very attractive for synchrotron light sources since they allow increasing the flux and/or the photon energy with respect to permanent magnet IDs. Babcock Noell GmbH (BNG) is completing the fabrication of a 1.5 m long unit for ANKA at FZK. The period length of the device is 15 mm for a total of 100.5 full periods plus an additional matching period at each end. The key specifications of the system are: a K value higher than 2 and the capability of withstanding a 4 W beam heat load and a phase error of 3.5 degrees. In addition, during the injection phase of the machine, the nominal gap of 5 mm can be increased up to 25 mm. The magnets have been tested with liquid helium in a vertical dewar and are now being installed in the cryostat. This paper describes the technical design concepts of the device and the status of the assembly process.

 
WE5RFP068 Design, Development and Testing of Diagnostic Systems for Superconducting Undulators 2417
 
  • M. Hagelstein, T. Baumbach, S. Casalbuoni, A.W. Grau, B. Kostka, R. Rossmanith, D. Saez de Jauregui
    FZK, Karlsruhe
  • A. Bernhard, D. Wollmann
    KIT, Karlsruhe
  • J. Chavanne, P. Elleaume
    ESRF, Grenoble
  • B. Diviacco
    ELETTRA, Basovizza
  • E.M. Mashkina
    University Erlangen-Nurnberg, Institute of Condensed Matter Physics, Erlangen
  • E.J. Wallén
    MAX-lab, Lund
 
 

Within the framework of a joint research activity of the European project IA-SFS (RII3-CT2004-506008) four synchrotron facilities have jointly developed diagnostic systems for superconducting undulators. Four work packages have been successfully completed: Design and construction of a test cryostat for field measurements; design and construction of a mock-up coil; field measurement and field error compensation; diagnostics and measurement of the spectrum of low energy electrons responsible for beam heat load in a superconducting undulator. The development advanced the knowledge of magnetic field error compensation considerably and might be of help in understanding the different beam heat load sources. Based on the development a second generation planar superconducting undulator with 15 mm period length for the synchrotron light source ANKA has been specified and procured.

 
WE5RFP087 Experimental Demonstration of the Induction Shimming Concept in Superconductive Undulators 2474
 
  • D. Wollmann, T. Baumbach, A. Bernhard, P. Peiffer
    KIT, Karlsruhe
  • A.W. Grau, R. Rossmanith
    FZK, Karlsruhe
  • E.M. Mashkina
    University Erlangen-Nuernberg, Erlangen
 
 

Recently a new concept for automatically reducing magnetic field errors in superconductive undulators was proposed. According to this proposal the field errors are compensated by an array of coupled high temperature superconductor loops attached to the surface of the superconductive undulator. The field errors induce currents in the coupled type II-superconducting loops and, as a result, the magnetic field generated by these currents minimizes the field errors. In this paper the results of a first successful experimental test of this concept are described.