Paper | Title | Page |
---|---|---|
TU5PFP065 | FZJ HIPPI SC Triple-Spoke Cavity | 978 |
|
||
The paper describes the design, fabrication and first test results of the triple-spoke cavity (resonant frequency 352 MHz, beta=0.48) developed at Forschungszentrum Jülich in the frame of High Intensity Pulsed Proton Injector project. The cavity has 5 cm diameter beam aperture, a transverse radius of 21.7 cm and the whole length of 78 cm. An initial wall thickness of niobium sheets used for cavity fabrication was around 4 mm. The RF cavity design has been adapted to two main goals - the simplest technology of cavity manufacture and for the prime goal of the project to achieve the best possible structural parameters (Lorenz force frequency shift and a resonant frequency pressure dependence). Intense cavity structural analyses have been conducted and the further prospectives on cavity developments are also presented. Construction of the niobium cavity prototype has been completed, the cavity has been chemically processed. Results of initial cold test are discussed. |