Paper | Title | Page |
---|---|---|
TU5PFP028 | High-Gradient RF Breakdown Studies with Narrow Waveguide | 879 |
|
||
High-gradient RF breakdown studies have been in progress at Nextef (New X-band Test Facility at KEK) since 2006. To study the characteristics of different materials on high-field RF breakdown, we have performed high-gradient experiments by using narrow waveguides that has a field of around 140 MV/m at 50 MW power. Breakdown rates of stainless-steel and copper cases were measured and the results are described in this paper. |
||
TU5PFP086 | Status of RF Sources in Super-Conducting RF Test Facility (STF) at KEK | 1032 |
|
||
The super-conducting RF test facility (STF) at KEK has been functional since 2005, and the STF phase-I, which involves the testing of a cryomodule with four superconducting cavities, was performed at the end of 2008. In this test, intense study of the power distribution system for the possible linear collider scheme was performed. Linear power distribution and tree-like distribution were compared and also the effects of eliminating circulator are studied. Current status of RF source of KEK STF are reported. |
||
TU5RFP081 | Status of the Energy Recovery Linac Project in Japan | 1278 |
|
||
Future synchrotron light source project using an energy recovery linac (ERL) is under proposal at the High Energy Accelerator Research Organization (KEK) in collaboration with several Japanese institutes such as the JAEA and the ISSP. We are on the way to develop such key technologies as the super-brilliant DC photo-injector and superconducting cavities that are suitable for both CW and high-current operations. We are also promoting the construction of the Compact ERL for demonstrating such key technologies. We report the latest status of our project, including update results from our photo-injector and from both superconducting cavities for the injector and the main linac, as well as the progress in the design and preparations for constructing the Compact ERL. |
||
WE5PFP081 | Digital Low-Level RF Control System with Four Intermediate Frequencies at STF | 2198 |
|
||
Digital low-level rf (LLRF) control system has been installed in many linear accelerators to stabilize the accelerating field. In the digital LLRF system, the rf signal is down-converted into intermediate frequency for sampling at analog-to-digital converter (ADC) and the number of ADC required for vector sum feedback operation is equal to the number of cavity. In order to decrease the number of the ADCs required, a digital LLRF control system using different four intermediate frequencies has been developed at STF (Superconducting RF Test Facility) in KEK. This digital LLRF control system was operated with four superconducting cavities and the rf field stability under feedback operation was estimated. The result of the performance will be reported. |
||
WE5PFP083 | Vector-Sum Control of Superconducting RF Cavities at STF | 2204 |
|
||
Vector-sum control of 4 superconducting cavities is examined at STF in KEK. The digital llrf control is carried out and the stabilities of rf fields are obtained. Various studies such as feedback margin necessary for enough field regulation, effects of perturbations of cavity detuning or klystron HV and so on. Performance degradation by elimination of circulators is also studied from the viewpoint of llrf system. |
||
WE5PFP084 | Evaluation of LLRF Stabilities at STF | 2207 |
|
||
In STF phass-1, four-cavities are operated with vector-sum feedback (FB) control. The FB control instabilities arising from passband of TM010 mode other than π mode with FB loop-delays were measured. Further, a feedforward (FF) table was used in combination with FB control, which improved the flatness of the flat-top region. A method for reduction of overshoot in FB + FF operation is also proposed. By electrically developing a quasi-beam, the response for quasi-beam injection was also measured, and the correction on beam-loading was performed. |
||
WE5PFP088 | Direct Sampling of RF Signal for 1.3 GHz Cavity | 2216 |
|
||
Intermediate-frequency conversion technique has been widely used for rf signal detection. However, this technique has disadvantages such as temperature dependence higher order modes of downconverters. One of our recent attractive developments is the high-speed data acquisition system that combines commercial FPGA board ML555 and fast ADC (ADS5474 14bit, maximum 400MS/s and bandwidth of 1.4 GHz). Direct measurements of 1.3 GHz rf signals are carried out with 270 MHz sampling. The direct sampling method can eliminate a down-converter and avoid calibration of non-linearity of the down-converter. These results are analyzed and compared with conventional measurement system. |