Paper | Title | Page |
---|---|---|
TU6PFP050 | Exploring the Feasibility of a Stand Alone Muon Facility for MuSR Research | 1394 |
|
||
The current paper discusses possible designs for a high intensity stand alone muon source for muSR studies of condensed matter. In particular we shall focus upon the potential implementation of a new generation of high power but relatively compact and cost effective proton drivers based on non-scaling fixed field alternating gradient (ns-FFAG) accelerator technology. The technical issues which must be addressed are also considered. |
||
WE6RFP039 | Solid Target for a Neutrino Factory | 2878 |
|
||
Funding: Science and Technology Facilities Council (United Kingdom) The UK programme of high power target developments for a Neutrino Factory is centred on the study of high-Z materials (tungsten, tantalum). A description of lifetime shock tests on candidate materials is given as a part of the research into a solid target solution. A fast high current pulse is applied to a thin wire of the sample material and the lifetime measured from the number of pulses before failure. These measurements are made at temperatures up to ~2000 K. The stress on the wire is calculated using the LS-DYNA code and compared to the stress expected in the real Neutrino Factory target. It has been found that tantalum is too weak at these temperatures but a tungsten wire has reached over 26 million pulses (equivalent to more than ten years of operation at the Neutrino Factory). Measurements of the surface velocity of the wire using a laser interferometry system (VISAR) are in progress, which, combined with LS-DYNA modelling, will allow the evaluation of the constitutive equations of the material. An account is given of the optimisation of secondary pion production and capture in a Neutrino Factory and of the latest solid target engineering ideas. |
||
TH4GAC03 | PAMELA Overview: Design Goals and Principles | 3142 |
|
||
Funding: EPSRC EP/E032869/1 The PAMELA (Particle Accelerator for MEdicaL Applications) project is to design an accelerator for proton and light ion therapy using non-scaling Fixed Field Alternating Gradient (FFAG) accelerators, as part of the CONFORM project, which is also constructing the EMMA electron model of a non-scaling FFAG at Daresbury. This paper presents an overview of the PAMELA design, and a discussion of the design goals and the principles used to arrive at a preliminary specification of the accelerator. |
||
|
||
TH5PFP041 | Particle Tracking Studies Using Dynamical Map Created from Finite Element Solution of the EMMA Cell | 3290 |
|
||
The unconventional size and the possibility of transverse displacement of the magnets in the EMMA non-scaling FFAG motivates a careful study of particle behavior within the EMMA ring. The magnetic field map of the doublet cell is computed using a Finite Element Method solver; particle motion through the field can then be found by numerical integration, using (for example) OPERA, or ZGOUBI. However, by obtaining an analytical description of the magnetic field (by fitting a Fourier-Bessel series to the numerical data) and using a differential algebra code, such as COSY, to integrate the equations of motion, it is possible to produce a dynamical map in Taylor form. This has the advantage that, after once computing the dynamical map, multi-turn tracking is far more efficient than repeatedly performing numerical integrations. Also, the dynamical map is smaller (in terms of computer memory) than the full magnetic field map; this allows different configurations of the lattice, in terms of magnet positions, to be represented very easily using a set of dynamical maps, with interpolation between the coefficients in different maps*. *yoel.giboudot@stfc.ac.uk |
||
TH6PFP022 | An FFAG Transport Line for the PAMELA Project | 3741 |
|
||
The PAMELA project to design an accelerator for hadron therapy using non-scaling Fixed Field Alternating Gradient (NS-FFAG) magnets requires a transport line and gantry to take the beam to the patient. The NS-FFAG principle offers the possibility of a gantry much smaller, lighter and cheaper than conventional designs, with the added ability to accept a wide range of fast changing energies. This paper will build on previous work to investigate a transport line which could be used for the PAMELA project. The design is presented along with a study and optimisation of its acceptance. |