Paper | Title | Page |
---|---|---|
TH6REP023 | Micron Size Laser-Wire System at the ATF Extraction Line, Recent Results and ATF-II Upgrade | 3997 |
|
||
Funding: STFC LC-ABD Collaboration, Royal Society, Daiwa Foundation, Commission of European Communities under the 6th Framework Programme Structuring the European Research Area, contract number RIDS-011899 The KEK Accelerator Test Facility (ATF) extraction line laser-wire system has been upgraded, enabling the measurement of micron scale transverse size electron beams. The most recent measurements using the upgraded system are presented, including the major hardware upgrades to the laser transport, the laser beam diagnostics line, and the mechanical control systems. |