A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Cheng, W.X.

Paper Title Page
TU3GRI03 NSLS-II Beam Diagnostics Overview 746
 
  • O. Singh, R. Alforque, B. Bacha, A. Blednykh, P. Cameron, W.X. Cheng, L.R. Dalesio, A.J. Della Penna, L. Doom, R.P. Fliller, G. Ganetis, R. Heese, H.-C. Hseuh, E.D. Johnson, B.N. Kosciuk, S.L. Kramer, S. Krinsky, J. Mead, S. Ozaki, D. Padrazo, I. Pinayev, V. Ravindranath, J. Rose, T.V. Shaftan, S. Sharma, J. Skaritka, T. Tanabe, Y. Tian, F.J. Willeke, L.-H. Yu
    BNL, Upton, Long Island, New York
 
 

A new 3rd generation light source (NSLS-II project) is in the early stage of construction at Brookhaven National Laboratory. The NSLS-II facility will provide ultra high brightness and flux with exceptional beam stability. It presents several challenges in the diagnostics and instrumentation, related to the extremely small emittance. In this paper, we present an overview of all planned instrumentation systems, results from research & development activities; and then focus on other challenging aspects.

 

slides icon

Slides

 
TU6RFP043 Optimization of the Booster to SPEAR Transport Line for Top-Off Injection 1641
 
  • J.A. Safranek, W.J. Corbett, X. Huang, J.J. Sebek
    SLAC, Menlo Park, California
  • W.X. Cheng
    BNL, Upton, Long Island, New York
 
 

Funding: Work supported by the US Department of Energy, Office of Basic Energy Sciences.


In the past, SPEAR3 has had typically 50 to 70% injection efficiency. Much of the lost injected beam hit the small gap vacuum chambers at the insertion devices. We are now implementing injection with photon beamline shutters open, so these losses create Bremsstrahlung down the photon beamlines, increasing radiation levels on the photon experimental floor. In this paper, we describe work done to better control the booster to SPEAR (BTS) transport line beam so as to reduce losses during injection. We have used new BTS BPM electronics to control the transport line trajectory. The trajectory response on these BPMs has been used to correct the BTS optics. We use turn-by-turn BPM readings of the injected beam in SPEAR to optimize the BTS trajectory in all six transverse and longitudinal coordinates. We use turn-by-turn profile measurements of the injected beam to verify the BTS optics correction. The stainless steel windows have been removed from the BTS vacuum system to reduce the transverse dimensions of the injected beam.

 
WE5RFP016 Short Bunch Measurements in SPEAR3 2300
 
  • W.J. Corbett, W.X. Cheng, X. Huang
    SLAC, Menlo Park, California
 
 

Funding: Work sponsored by U.S. Department of Energy Contract DE-AC03-76SF00515 and Office of Basic Energy Sciences, Division of Chemical Sciences.


Recent experimental results and advances in the theory of short-bunch dynamics have lead to an improved understanding of the parameters and limitations of short-bunch operation in storage rings. In this paper the measurement and analysis of short bunches under a variety of operational parameters is reported for SPEAR3.

 
TH6REP032 Fast-Gated Camera Measurements in SPEAR3 4015
 
  • W.X. Cheng, W.J. Corbett, A.S. Fisher, X. Huang, J.A. Safranek, A. Terebilo
    SLAC, Menlo Park, California
  • W.Y. Mok
    Life Imaging Technology, Palo Alto, California
 
 

Funding: Work sponsored by U.S. Department of Energy Contract DE-AC03-76SF00515 and Office of Basic Energy Sciences, Division of Chemical Sciences.


An intensified, fast-gated CCD camera was recently installed on the visible diagnostic beam line in SPEAR3. The ~2nS electronic gate capability, ability to make multiple-exposure images and to acquire sequences of images provides good diagnostic potential. Furthermore, the addition of a rotating mirror just upstream of the photocathode provides the ability to optically ‘streak’ multiple images across the photocathode. In this paper, we report on several fast-gated camera studies including (1) resonant excitation of vertical bunch motion, (2) imaging of the injected beam with and without emittance-spoiling windows in the upstream transfer line, (3) injection kicker tuning to minimize perturbations to the stored beam and (4) images of short-bunch ‘bursting’ in the low momentum-compaction mode of operation.

 
TH6REP033 Interferometer Beam Size Measurements in SPEAR3 4018
 
  • W.J. Corbett, W.X. Cheng, A.S. Fisher, E. Irish
    SLAC, Menlo Park, California
  • T.M. Mitsuhashi
    KEK, Ibaraki
  • W.Y. Mok
    Life Imaging Technology, Palo Alto, California
 
 

Funding: Work sponsored by U.S. Department of Energy Contract DE-AC03-76SF00515 and Office of Basic Energy Sciences, Division of Chemical Sciences.


A two-slit interferometer has been installed in the SPEAR3 diagnostic beam line to measure vertical beam size at a dipole source point. The diagnostic beam line accepts unfocused, visible light in a 3.5 x 6.0 mrad aperture so that at the slit location 17 m from the source, the vertical extent of the beam is 100mm. For typical source sizes of sigy~15 um (0.1% emittance coupling) a slit separation of 80 mm produces fringe visibility of order V=0.5. Hence a significant plot of fringe visibility vs. slit separation can be generated to infer source size via Fourier transformation. In this paper we report on the interferometer construction, beam size measurement and potential deficiencies of the system, and compare with theoretical results.