WE6RFP006 | Cryogenic Considerations on SRF Operation at 2K for a Light Source Using a Standard 4.5K Cryo-Plant | 2793 |
|
||
The feasibility of SRF operation at 2K using the remaining refrigeration capacity of an operating 4.5K cryogenic plant at NSRRC is examined. A refrigeration configuration with warm compression is proposed under an assumption that a reasonable amount of cryogenic heat load is required at 2K. The expectation of the efficacy of the cold and warm heat exchangers (HEX) is evaluated in terms of the corresponding equivalent cryogenic heat load on the 4.5K cold box. A factor approximately 9.5 or 6.0 is required to convert the cryogenic loss, 12 W at 2K, into our 4.5K cold box operated in a refrigeration mode without or with the cold heat exchanger (efficiency 85 %), respectively. An additional benefit is that the required volumetric pumping speed of the warm compressor can be greatly decreased. Moreover, a considerable cold capacity from the sub-atmospheric cold return helium gas can be ultimately converted by combining the cold HEX working together with a highly effective warm HEX, to a conversion factor 3.8 with an efficiency 95 %. Special attention must be devoted to minimize the risk of contamination or impurity for a turbine refrigerator. |