A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Bassanese, S.

Paper Title Page
TH5RFP055 Libera Brilliance Single Pass Position Measurements 3579
 
  • A. Kosicek, M. Znidarcic
    I-Tech, Solkan
  • S. Bassanese
    ELETTRA, Basovizza
 
 

Libera Brilliance is a standard device for beam position monitoring on circular synchrotron light sources. Initially, the idea of optimizing its signal processing for the single bunch measurement came from the users community. This was afterwards followed by the idea of using it on transfer lines on the same 3rd generation light sources as well as on injector system for the FELs. The device can be used on pickup buttons and on striplines. The single pass functionality is contained in newest Libera Brilliance software Release 2.0, no hardware changes are needed. The measurement principles and first measurements with results are presented.

 
TH6REP098 Preinjector Gun Upgrade, Timing and Synchronization and Preparation for the Top-Up Injection in Elettra 4183
 
  • A. Carniel, S. Bassanese, M. Ferianis, E. Karantzoulis, C. Scafuri, A. Vascotto
    ELETTRA, Basovizza
 
 

Elettra is the third generation light source in operation in Trieste since 1993,upgraded with a full energy booster injector last year. Top-up operation is on schedule in the near future but already the new timing system and gun are ready to operate in this mode. The paper describes all tasks and requirements needed to satisfy top-up injection include custom made hardware, interaction with controls and radiation protection system.