Paper | Title | Page |
---|---|---|
THP111 | Development of a 500-kV Photo-Cathode DC Gun for ERL Light Sources | 995 |
|
||
An electron gun capable of delivering high current and high brightness electron beam is indispensable for next generation energy recovery linac light sources. A high voltage photocathode DC gun is a promising gun for such new light sources. It is however difficult to apply DC high voltage on a ceramic insulator with a rod supporting cathode electrode because of field emission from the rod. In order to mitigate the problem, we have employed a segmented insulator with rings which guard the ceramics from the field emission and recently succeeded in applying 500-kV on the ceramics for eight hours without any discharge. This high voltage testing was performed with a simple configuration without NEG pumps and electrodes. The next step is to repeat the same high voltage testing with a full configuration necessary for beam generation. We have designed electrodes for the maximum surface electric field not to exceed 11 MV/m at 500 kV while keeping the distance between the electrodes 100 mm. NEG pumps with a pumping speed of 7200 L/s have been installed in the gun chamber. A photocathode preparation system was connected to the gun chamber and beam generation is planned this summer. |