A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Miura, A.

Paper Title Page
TUP067 Reduction of Transverse Emittance Growth in J-PARC DTL 563
 
  • H. Sako, M. Ikegami, A. Miura, G.H. Wei
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
 
 

Transverse emittance growth was observed in J-PARC Drift Tube Linac (DTL). In order to suppress the growth, we searched for optimum parameters at MEBT1, by measuring transverse emittance using four wire scanner monitors at the exit of DTL. At 15 mA peak beam current in Dec 2009, horizontal and vertical rms emittance was reduced by 12 % and 10 %, respectively, by setting the amplitudes of the first and second bunchers to 120 % and 90 % with respect to the designed settings. The resulting normalized horizontal and vertical emittance was 0.230 and 0.205 pi mm mrad. At 20 mA in Jan 2010, horizontal and vertical rms emittance was reduced by 17 % and 10 %, respectively, by setting the amplitudes of the first and second bunchers to 110 % and 80 % with respect to the designed settings. The resulting normalized horizontal and vertical emittance was 0.273 and 0.253 pi mm mrad. At 15 mA, we further reduced the horizontal and vertical emittance to 0.171 and 0.200 pi mm mrad by increasing the eighth quadruple magnet field at MEBT1 by 20 % to the designed value. The measured transverse emittance dependence on buncher electric field and quadruple magnetic field will be compared with simulation.

 
TUP075 Residual Gas Pressure Dependence of Beam Loss 587
 
  • A. Miura, M. Ikegami
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
  • H. Sako
    JAEA, Ibaraki-ken
  • G.H. Wei
    KEK/JAEA, Ibaraki-Ken
 
 

Residual gas in beam transport line essentially affects the beam loss and residual radiation on the accelerator. J-PARC linac is usually operated under 1.0 ·10-6 to 1.0 ·10-5 Pa in SDTL and A0BT sections. In this situation, no serious beam loss was observed during the beam operation. In future development of J-PARC linac, because the peak beam energy and output will be increased, it is getting more serious problem. Before the development, it is important to understand a cause of beam loss and relation between beam loss and residual gas pressure. We measured beam loss at the normal and worse vacuum condition in both SDTL and A0BT sections. The result indicates that the beam loss depends on the residual gas pressure and position where the beam loss occurs is about 20 to 30 meter downstream. This suggests the optimum position for installation of vacuum system to minimize the beam loss. In this paper, we describe the experimental result and its discussions. In addition, the cause of the beam loss is considered to be a stripping from negative hydrogen ions to neutral hydrogen atoms. This mechanism is also discussed in this paper.

 
TUP076 Status of Beam Loss Evaluation at J-PARC Linac 590
 
  • A. Miura, N. Kikuzawa, T. Maruta, K. Yamamoto
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
  • Z. Igarashi, T. Miyao
    KEK, Ibaraki
  • M. Ikegami
    J-PARC, KEK & JAEA, Ibaraki-ken
  • H. Sako
    JAEA, Ibaraki-ken
  • S. Sato
    JAEA/LINAC, Ibaraki-ken
 
 

Since November, 2007, J-PARC Linac has been operated at 7.2kW beam power. During the operation, beam losses possibly caused by the H0 particles generated by the interaction between H- beam and residual gas in the transport line were observed in the SDTL (Separated-type Drift-Tube Linac) section. In the linac operation, Ar-CO2 gas proportional counters are employed for the measurement of beam loss, but they are also sensitive to background noise of X-ray emitted from RF cavities. In this section, protons, secondary hadrons and gamma rays would be mainly generated as a beam loss, but it is not easy to estimate real beam loss using the proportional counter. The plastic scintillation counters with less X-ray sensitivity and 3He proportional counters with high thermal neutron sensitivity will be also employed to measure the beam loss. The combination of these detectors would bring more accurate beam loss measurements with suppression of X-ray noise. A measurement of emission position and angle distributions of protons due to H- beam loss is being planed. This result would lead to clarify the source of beam loss. This paper reports status of beam loss evaluation using these detectors.