Paper | Title | Page |
---|---|---|
TUP033 | Commissioning of the IH Linac and High Energy Beam Transport of the EBIS Based Preinjector for RHIC | 470 |
|
||
The EBIS based preinjector for RHIC is now being commissioned. The Linac was delivered in April 2010 and commissioning started in May, 2010. It accelerates ions from 0.3 MeV/u to 2 MeV/u with 27 accelerating gaps, one internal quadrupole triplet, and operates at 100.625 MHz. The Linac is followed by a beam transport line to Booster which includes seven quadrupoles, two bunchers, and an achromatic bend system with resolution of 500 at 2 MeV/u to select the required charge state. Diagnostics include a pepperpot emittance probe, phase probes , fast Faraday cup, adjustable slits, three sets of multiwire profile monitors, three current transformers, two Faraday cups, and two beam stops. This contribution will report results of linac tuning and cold measurements, and commissioning of the Linac and high energy transport line with helium and gold beams. |
||
TUP034 | Beam Commissioning Results for the RFQ and MEBT of the EBIS Based Preinjector for RHIC | 473 |
|
||
The EBIS based preinjector for the RHIC is now being commissioned. During the step-wise commissioning of the preinjector from January 2009 to June 2010, the RFQ was commissioned first using Test EBIS in January 2009 and then moved to its final location and commissioned again with RHIC EBIS in March 2010. The RFQ accelerates ions from 17 keV/u to 300 keV/u and operates at 100.625 MHz. The RFQ is followed by a short (81 cm) Medium Energy Beam Transport (MEBT), which consists of four quadrupoles and one buncher cavity. Temporary diagnostics for this commissioning included an emittance probe, TOF system, fast Faraday cup, and beam current measurement units. This contribution will report results of RFQ and MEBT commissioning with helium and gold beams. |
||
FR103 | Commissioning of the EBIS-Based Heavy Ion Preinjector at Brookhaven | 1033 |
|
||
This talk will present commissioning of a new heavy ion pre-injector at Brookhaven National Laboratory. This preinjector uses an Electron Beam Ion Source (EBIS), and an RFQ and IH Linac, both operating at 100.625 MHz, to produce 2 MeV/u ions of any species for use, after further acceleration, at the Relativistic Heavy Ion Collider, and the NASA Space Radiation Laboratory. Among the increased capabilities provided by this preinjector are the ability to produce ions of any species, and the ability to switch between multiple species in 1 second, to simultaneously meet the needs of both physics programs. |
||
|
||
Longer Pulse Acceleration Using RFQ and Laser Ion Source | ||
|
||
It was proved that direct plasma Injection Scheme (DPIS) is an efficient way to accelerate high current highly charged state heavy ion beam. More than 50 mA (peak current) of various heavy ion beams were accelerated in BNL, RIKEN and TITech. However, it was rather difficult to obtain longer pulse especially for highly charged particles. To induce highly charged states ions, a high plasma temperature is required at the laser irradiation point and the high temperature automatically gives a very fast expansion velocity of the plasma. This shortens the ion beam pulse length. To compensate the shorter ion pulse length, we can extend the plasma drift length, but it will dilute the brightness of the plasma since the plasma expands three dimensionally. To avoid the reduction of the brightness, a simple long solenoid was applied to confine the diverging angle of the plasma. In the conference, this new technique will be explained and the latest results will be shown. |