A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Jones, S.L.

Paper Title Page
MOP089 Spallation Neutron Source High-Power Protection Module Test Stand 262
 
  • S.W. Lee, J.A. Ball, T.L. Davidson, S.L. Jones
    ORNL RAD, Oak Ridge, Tennessee
  • M.T. Crofford, T.W. Hardek
    ORNL, Oak Ridge, Tennessee
 
 

The Spallation Neutron Source (SNS) High-Power Protection Module (HPM) provided interlocks and fast shutdown for the RF system to protect the accelerating structures and high power RF (HPRF) Distribution System. The HPM has required some functionality upgrades since the start of beam operations and an upgrade to the HPM test stand was required to support these added features. The HPM test stand currently verifies functionality, RF channel calibration, and measurement of the speed of shutdown to ensure the specifications are meet. The upgraded test stand was implemented in a single FPGA to allow for future growth and flexibility. Work is currently progressing on automation of the test stand to better perform the required module calibration schedule.