A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Guo, Z.D.

Paper Title Page
THP120 First Test Result of the IHEP-01 Large Grain 9-Cell Cavity 1022
 
  • J. Gao, J.P. Dai, Z.D. Guo, M. Hou, Z.Q. Li, L.L. Men, Q.Y. Wang, Q. Xiao, J.Y. Zhai
    IHEP Beijing, Beijing
  • H. Hayano, E. Kako, S. Noguchi, M. Sawabe, T. Shishido, N. Toge, K. Watanabe, Y. Yamamoto
    KEK, Ibaraki
  • T.X. Zhao
    IHEP Beiing, Beijing
 
 

The combination of the low-loss shape and large grain niobium material is expected to be the possible way to achieve higher gradient and lower cost for ILC 9-cell cavities. As the key component of the 'IHEP 1.3 GHz SRF Accelerating Unit and Horizontal Test Stand Project', a low-loss shape 9-cell cavity using Ningxia large grain niobium (IHEP-01) was fabricated and surface treated (CBP, CP, annealing, pre-tuning) at IHEP. Then the cavity was shipped to KEK STF for ultrasonic cleaning, high pressure rinsing, baking and vertical test. The cavity reached 20 MV/m in the first vertical test on July 1st 2010. The quench location has been found by T-mapping and optical inspection. The strong field emission and equator defects will be removed by further treatment. The fabrication procedure, surface treatment recipes and the first test results are summarized in this paper.