Non-uniform temperature distribution, surface roughness, and superfluid helium level change between 2K dewar and cryomodule are most important thermal analyses in designing cryogenic system. Effective temperature for non-uniform temperature distribution is defined. Thermal radiation property from surface roughness which is related to fractional dimension is investigated. Superfluid helium level change between 2K dewar and cryomodule is shown as a function of temperature difference. Our research can be useful thermal analyses for cryogenic system design.
|
|