Paper |
Title |
Page |
WEPME020 |
Commissioning of the MICE RF System |
2297 |
|
- A.J. Moss, A.E. Wheelhouse
STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
- S.M.H. Alsari
Imperial College of Science and Technology, Department of Physics, London, United Kingdom
- A.J. Dick, K. Ronald, D.C. Speirs, C.G. Whyte
USTRAT/SUPA, Glasgow, United Kingdom
- T. Stanley
STFC/RAL, Chilton, Didcot, Oxon, United Kingdom
- C.J. White
STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
|
|
|
The Muon Ionisation Cooling Experiment (MICE) is being constructed at Rutherford Appleton Laboratory in the UK. The muon beam will be cooled using multiple hydrogen absorbers then reaccelerated using an RF cavity system operating at 201MHz. This paper describes recent progress in commissioning the amplifier systems at their design operation conditions, installation and operation within the Ionisation Cooling Test Facility (ICTF) as part of the MICE project.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2014-WEPME020
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPRI058 |
RF Delivery System for FETS |
3902 |
|
- S.M.H. Alsari, M. Aslaninejad, J.K. Pozimski, P. Savage
Imperial College of Science and Technology, Department of Physics, London, United Kingdom
- M. Dudman, A.P. Letchford
STFC/RAL, Chilton, Didcot, Oxon, United Kingdom
|
|
|
The Front End Test Stand (FETS) is an experiment based at the Rutherford Appleton Laboratory (RAL) in the UK. In this experiment, the first stages necessary to produce a very high quality, chopped H− ion beam as required for the next generation of high power proton accelerators (HPPAs) are designed, built and tested. HPPAs with beam powers in the megawatt range have many possible applications including drivers for spallation neutron sources, neutrino factories, accelerator driven sub-critical systems, waste transmuters and tritium production facilities. An RF system outline, circulator high power tests, RF amplifiers tests, waveguide run with shielding and couplers design are presented and discussed in this paper. Experimental measurements of the system’s circulator and RF Amplifiers high power test will be presented as part of the system testing results.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2014-THPRI058
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|