| Paper | 
        Title | 
        Page | 
    
    
        | MOPC105 | 
        Design of the High Beta Cryomodule for the HIE-ISOLDE Upgrade at CERN | 
        319 | 
    
    
        |   | 
        
                - L.R. Williams, A.P. Bouzoud, N. Delruelle, J. Gayde, Y. Leclercq, M. Pasini, J.Ph. G. L. Tock, G. Vandoni
 
                       CERN, Geneva, Switzerland 
          | 
          | 
    
        
            |   | 
            
            The major upgrade of the energy and intensity of the radioactive ion beams of the existing ISOLDE and REX-ISOLDE facilities at CERN will, in the long term, require downstream of the existing machine, the installation of four high-β and two low-β cryo-modules. The first stage of this upgrade, involving the design, construction, installation and commissioning of two high-β cryo-modules is approved and design work is underway at CERN. The high-β cryo-module houses five high-β superconducting cavities and one superconducting solenoid. As well as providing optimum conditions for physics, where the internal active components must remain aligned within tight tolerances, the cryo-modules need to function under stringent common vacuum and cryogenic conditions. To preserve the RF cavity performance their assembly and sub-system testing will need to be carried out using specifically designed tooling in a class 100 clean-room. We present the determining factors constraining the design of the high-β cryo-module together with the design choices that these factors have imposed.
             | 
              | 
          
        
            |   |