Author: Gallagher, A.
Paper Title Page
WEPC158 The EMMA Accelerator, A Diagnostic Systems Overview 2355
 
  • R.J. Smith, M. Dufau, C. Hill, J.K. Jones, A. Kalinin, L. Ma, P.A. McIntosh, B.D. Muratori, B.J.A. Shepherd
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • J.S. Berg
    BNL, Upton, Long Island, New York, USA
  • N. Bliss, G. Cox, A. Gallagher, A. Oates
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • R.G. Borrell
    WareWorks Ltd, Manchester, United Kingdom
  • J.L. Crisp
    FRIB, East Lansing, Michigan, USA
  • K.M. Hock, D.J. Holder
    Cockcroft Institute, Warrington, Cheshire, United Kingdom
  • M.G. Ibison, I. Kirkman
    The University of Liverpool, Liverpool, United Kingdom
  • D.J. Kelliher, S. Machida
    STFC/RAL/ASTeC, Chilton, Didcot, Oxon, United Kingdom
 
  The ‘EMMA’ Non-Scal­ing Fixed Field Al­ter­nat­ing Gra­di­ent (NS-FFAG) in­ter­na­tion­al pro­ject is cur­rent­ly being com­mis­sioned at Dares­bury Lab­o­ra­to­ry, UK. This ac­cel­er­a­tor has been equipped with a num­ber of di­ag­nos­tic sys­tems to fa­cil­i­tate this. These sys­tems in­clude a novel time-do­main-mul­ti­plex­ing BPM sys­tem, move­able screen sys­tems, a time-of-flight in­stru­ment, Fara­day cups, and in­jec­tion/ex­trac­tion to­mog­ra­phy sec­tions to anal­yse the sin­gle bunch beams. An up­grade still to im­ple­ment in­cludes the in­stal­la­tion of a fast wall cur­rent mon­i­tor. This paper gives an overview of these sys­tems and shows some data and re­sults that have con­tribut­ed to the suc­cess­ful demon­stra­tion of a ser­pen­tine ac­cel­er­a­tion by this novel ac­cel­er­a­tor.