TUPEC031 The Operation of Injection System in the SSRF 1788
 
  • M. Gu, Z.H. Chen, B. Liu, L. Ouyang, R. Wang, Y. Wu, Q. Yuan
    SINAP, Shanghai
 
 

The injection system composed of four kickers and two septa in the SSRF have been built and operated. The commissioning shows that fine injecting efficiency and smaller disturbance are carried out. The septum magnets are eddy current designs with a sheet of magnetic screening material around the stored electron beam to reduce the leakage field. The beam tube with RF finger flanges at each end is added to keep the continuity of impedance for the circulating beam. The pulser excite the septum with 60μsecond waveform of half sine-wave and 8kA peak current. Four identical kicker magnets provide the symmetric bump in 10 meter long straight sections. The excitation waveform is a 3.8μsecond half sine pulse up to 7 kA peak. The emphasis was on achieving the best possible tracking in time of the magnet field waveforms so that the residual closed orbit disturbance is minimized for top-up injection. The performance of the injection system with these pulsed magnets are described.