Paper | Title | Page |
---|---|---|
WEPEA083 | Application of Model Independent Analysis with EPICS-DDS | 2675 |
|
||
Model Independent Analysis (MIA) is an essential approach for measuring optical properties of accelerators. In the paper, we evaluate its application in the context of the NSLS-II Light Source storage ring. It is the first application of the new high-level application environment based on the EPICS-DDS middle layer. Using a full-scale virtual accelerator, the paper explores the tolerance of the MIA approach against the different conditions such as measurement noise in the beam position monitors, magnet errors, misalignments, etc. |
||
WEPEB022 | The NTMAT EPICS-DDS Virtual Accelerator for the Cornell ERL Injector | 2734 |
|
||
Commissioning of the high brightness photoinjector for the Energy Recovery Linac at Cornell University continues. To aid in this process we have developed a 'Virtual Accelerator' application, which provides the beam physicist with an online high-level physics description of the machine. This application combines a linear optics model called Numerical Transfer Matrix (NTMAT), developed at Cornell, and EPICS-DDS, a middle-layer software based on the Experimental Physics and Industrial Control System (EPICS) toolkit and the Data Distribution Service (DDS) data-centric publish/subscribe model. We present the initial results of implementing this new software tool and its deployment in the Cornell ERL injector control room. |