Paper | Title | Page |
---|---|---|
MOPE022 | Development of Shintake Beam Size Monitor for ATF2 | 1011 |
|
||
In this paper, we describe a system design and current status of Shintake beam size monitor. Shintake monitor is a laser-based beam diagnostics tool, which provides a non-invasive measurement of transverse beam sizes. The interaction target probing the electron beam is interference fringes build up by the two coherent lasers that have narrow bandwidth and long coherent length. A scale of the target structure corresponds to approximately one fourth of the laser wave length, and the smallest measurable size reaches down to several tens of nanometers. The monitor we described here is installed at the virtual interaction point of the ATF2 beam line, which is built to confirm the proposed final focus system for Future Linear Colliders. We adopt second harmonics of Nd:YAG laser of 532 nm wavelength, and phase stabilization feedback system to allow to measure the designed beam size of about 37 nm. To widen a measurable range up to about 5 microns (wire scanner's range), we also prepare three crossing modes that change an effective wavelength for the fringes. The monitor is used to measure a focus size during the tuning process. The system is based on the Shintake monitor for FFTB. |
||
MOPE023 | Evaluation of Expected Performance of Shintake Beam Size Monitor for ATF2 | 1014 |
|
||
ATF2 is the final focus test facility for ILC to realize and demonstrate nanometer focusing. One of the goals of the ATF2 is a demonstration of a compact final focus system based on the local chromaticity correction. A designed beam size at the focal point is to be 37 nm in vertical. To achieve the goal, a beam size monitor capable of nanometer beam size measurement is inevitably needed. Shintake monitor satisfies the demands, and is installed at the virtual interaction point of the ATF2. Shintake monitor is a beam size monitor which uses laser interference fringe pattern to measure beam size. The beam test for the Shintake monitor was successful in measurement of signal modulation with the laser interference fringe pattern in November 2009. In April 2010, beam size of less than 1 micron was achieved. We have studied the error sources, and evaluated the total error to be less than 10% for 1 minute measurement. This paper is about the evaluation of the Shintake monitor performance by analyzing beam tests data. Most systematic error sources are well understood, so that we can estimate accuracy of beam size measurement when the beam size reaches 37nm. |