MOPD004 Magnetic Field Correction in Normal Conducting Synchrotrons 675
 
  • E. Feldmeier, Th. Haberer, A. Peters, C. Schömers, R. Steiner
    HIT, Heidelberg
 
 

While ramping the magnets in a synchrotron the magnetic fields deviate from their set values. Especially the field errors in dipole and quadrupole magnets result in different problems during operation. At the Heidelberg Ion Therapy Center HIT a measuring system with extremely high precision has been developed. It can measure in real time integral magnetic fields with a precision of better than 5*10-5 in a reproducible way. A feed-back control system for the magnetic fields is being installed and will be operational in May 2010. This control loop lets the magnets reach the nominal field much faster and thus shortens the dead time in a synchrotron cycle. The cycle can be reduced by 30% and more patients can be treated.