A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Sawada, S.

Paper Title Page
MOPE024 Development of Radiation Registant Optics System for High Intensity Proton Beamline at the J-PARC 1017
 
  • A. Toyoda, A. Agari, E. Hirose, M. Ieiri, Y. Katoh, A. Kiyomichi, M. Minakawa, T.M. Mitsuhashi, R. Muto, M. Naruki, Y. Sato, S. Sawada, Y. Suzuki, H. Takahashi, M. Takasaki, K.H. Tanaka, H. Watanabe, Y. Yamanoi
    KEK, Tsukuba
  • H. Noumi
    RCNP, Osaka
 
 

Optical beam measurement such as OTR(Optical Transition Radiation), ODR(Optical Diffraction Radiation), gas Cerenkov, and so on is a powerful tool to observe a two-dimensional information of high intensity beam profile, so that this method is widely used at various electron and hadron accelerators. However, high radiation field to damage an optical system gradually becomes a major issue with increasing the beam intensity to explore new physics. Our present effort is devoted to develop a high efficient optical system to resist such high radiation field. We newly designed an optical system composed of two spherical mirrors which do not have any lenses vulnerable to radiation. Detailed optics design and a result of optical performance test will be presented. Also we will report a result of a beam test experiment of this optics system combined with an OTR screen performed at high intensity proton extraction beamline of the J-PARC.

 
THPEC045 Electrostatic Separator and K1.8 Secondary Beamline at the J-PARC Hadron-Hall 4161
 
  • M. Ieiri, A. Agari, E. Hirose, Y. Katoh, M. Minakawa, R. Muto, M. Naruki, Y. Sato, S. Sawada, Y. Suzuki, H. Takahashi, T. Takahashi, M. Takasaki, K.H. Tanaka, A. Toyoda, H. Watanabe, Y. Yamanoi
    KEK, Tsukuba
  • H. Noumi
    RCNP, Osaka
 
 

In the hadron experimental hall at the 50-GeV Proton Synchrotron (PS) of J-PARC, the secondary beam line K1.8 with double stage separator is expected to provide 1-2 GeV/c kaon beams with less contamination of pions mainly for hadron and nuclear physics experiments with strangeness. An electrostatic (ES) separator is one of key elements of this secondary beam line. The ES separator will generate a 75kV/cm electrostatic field between parallel electrodes of 10cm gap and 6m in length along the beam direction. It is designed so as to be radiation-proof and to lower spark rate at the high intensity proton accelerator facility. The K1.8 line has two 6m ES separators with the intermediate focal point upstream of separators to reduce the pion backgrounds from the production target. The K-/π- ratio of the line is expected to have a larger value than 1 at the experimental target. Beam commissioning of the K1.8 has just started. We will report separator performance, optics design of the K1.8 beam line and the first result of the beam commissioning.

 
THPEB014 Status and Upgrade Plan of Slow Extraction from the J-PARC Main Ring 3912
 
  • M. Tomizawa, T. Adachi, Y. Arakaki, A. Kiyomichi, S. Murasugi, R. Muto, H. Nakagawa, K. Niki, K. Okamura, Y. Sato, S. Sawada, Y. Shirakabe, H. Someya, K.H. Tanaka, T. Toyama, E. Yanaoka
    KEK, Ibaraki
  • A. Ando, Y. Hashimoto, T. Koseki, J. Takano
    J-PARC, KEK & JAEA, Ibaraki-ken
  • D. Horikawa, I. Sakai
    University of Fukui, Faculty of Engineering, Fukui
  • K. Mochiki, S. Onuma
    Tokyo City University, Tokyo
  • H. Sato
    Tsukuba University, Ibaraki
  • A. Schnase
    JAEA/J-PARC, Tokai-mura
 
 

High power protons from the J-PARC main ring is slowly extracted using the third integer resonance and delivered to the experimental hall for various nuclear and particle physics experiments. The slow extraction device comprises two electro static septa (ESS),ten magnetic septa, four bump magnets, eight resonant sextupole magnets and their power supply. One of the critical issue of the slow extraction is radiation caused by the beam loss during the slow extraction. We have developed the electrostatic and magnetic septa with thin septum thickness. A unique scheme with large step size and small angular spread of the extracted beam enables hit rate on the ESS less than 1% level. In January 2009, first 30 GeV proton beam has been successfully delivered to the fixed target. Quadrupole magnets and a DSP feedback control system to obtain a uniform beam spill structure were implemented in 2009 summer shutdown period. We will report the extraction efficiency, extracted beam profiles and spill structure obtained by the beam commissioning so far. We will also mention a upgrade plan based on some new ideas to aim a higher performance.

 
THPEB022 Beam Spill Control for the J-PARC Slow Extraction 3933
 
  • A. Kiyomichi, T. Adachi, A. Akiyama, S. Murasugi, R. Muto, H. Nakagawa, J.-I. Odagiri, K. Okamura, H. Sato, Y. Sato, S. Sawada, H. Someya, K.H. Tanaka, M. Tomizawa, A. Toyoda
    KEK, Tsukuba
  • T. Kimura
    Miyazaki University, Miyazaki
  • K. Mochiki, S. Onuma
    Tokyo City University, Tokyo
  • K. Noda
    NIRS, Chiba-shi
 
 

The slow extraction beam from the J-PARC Main Ring (MR) to the Hadron Experimental Facility is used in various nuclear and particle physics experiments. A flat structure and low ripple noise are required for the spills of the slow extraction. The spill control system has been developed for the J-PARC slow extraction to make a flat structure and small ripple. It consists of the extraction quadrupole magnets and feedback device. The extraction magnets consist of two kinds of quadrupole magnets, EQ (Extraction Q-magnet) which make flat beam and RQ (Ripple Q-magnet) which reject the high frequent ripple noise. The feedback system, which is using Digital Signal Processor (DSP), makes a ramping pattern for EQ and RQ from spill beam monitor. The extraction magnets and feedback device were installed in September 2009, and spill feedback study were successfully started from the beam time in October 2009. Here we report the operation status of magnets and first study of beam commissioning with spill feedback.