TUPEA031 | Synchronization and Control System for Tsinghua Thomson Scattering X-ray Source | 1393 |
|
||
The Tsinghua Thomson scattering X-ray source (TTX) has a strict laser-electron synchronization requirement and a comprehensive system structure including dual high-power laser system, RF system and beam diagnostic instruments, etc. Recently, a synchronization and control system is developed to meet these requirements, which includes a laser-RF synchronizer with 100fs time jitter, a FPGA based event generator for laser and RF systems with 250ps time resolution, and an EPICS based control system for system integration and remote monitor and control. The electron bunch arrival time jitter is carefully measured and analyzed with the help of a RF deflecting cavity. This paper reports the development status, technical implementation, and measurement results of the synchronization and control system. |