A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Nordlund, D.

Paper Title Page
TUPE065 Surface Characterization of the LCLS RF Gun Cathode 2284
 
  • A. Brachmann, F.-J. Decker, Y.T. Ding, D. Dowell, P. Emma, J.C. Frisch, A. Gilevich, G.R. Hays, P. Hering, Z. Huang, R.H. Iverson, H. Loos, A. Miahnahri, D. Nordlund, H.-D. Nuhn, P.A. Pianetta, J.L. Turner, J.J. Welch, W.E. White, J. Wu, D. Xiang
    SLAC, Menlo Park, California
 
 

Surface characterization of the LCLS RF gun cathode A. Brachmann On behalf of the LCLS commissioning team The first copper cathode installed in the LCLS RF gun was used during LCLS commissioning for more than a year. However, after high charge operation (~ 500 pC), the cathode showed a decline of quantum efficiency due to surface contamination caused by residual ionized gas species present in the vacuum system. We report results of SEM, XPS and XAS studies that were carried out on this cathode after it was removed from the gun. X-ray absorption and X-ray photoelectron spectroscopy reveal surface contamination by various hydrocarbon compounds. In addition we report on the performance of the second installed cathode with emphasis on the spatial distribution of electron emission.