Paper | Title | Page |
---|---|---|
WEPEB055 | Straightness Alignment of Linac by Detecting Slope Angle | 2815 |
|
||
Profile shape measurements detecting profile slope angle, which corresponds to the differential of the profile shape, have been used for evaluating profile shapes highly precisely. They are hardly affected by scanning error in measurement and considered to have advantages for long distance measurements. Here, profile measurement using a level was adopted for straightness alignment of the KEK e-/e+ injector linac, considering the straightness alignment as a profile shape measurement. The slope angles between the alignment base plates of the linac could be detected with reproducibility of 10 micro-rad (σ) by sequential measurement interval of 1 to 2 m. The reproducibility of the straightness derived from the angle measurements was 42 micrometer (σ) for 69 m of the measurement distance and agreed well with the estimated value based on our error propagation model. These results show that straightness reproducibility of better than 1 mm (2-σ) can be achieved for 500 m of the KEK e-/e+ injector linac by sampling interval of 2m, and for 10 km of the ILC linac by sampling interval of 20 cm. |
||
WEPE041 | A Superconducting Magnet Upgrade of the ATF2 Final Focus | 3440 |
|
||
The KEK ATF2 facility, with a well instrumented beam line and Final Focus (FF), is a proving ground for linear collider (LC) technology to demonstrate the extreme beam demagnification and spot stability needed for a LC FF*. ATF2 uses water cooled magnets but the baseline ILC calls for a superconducting FF**. Thus we plan to replace some ATF2 FF magnets with superconducting ones made via direct wind construction as planned for the ILC. With no cryogenic supply at ATF2, we look to cool magnets and current leads with a few cryocoolers. ATF2 FF coil winding is underway at BNL and production warm magnetic measurements indicate good field quality. Having FF magnets with larger aperture and better field quality than present FF might allow reducing the beta function at the FF for study of focusing regimes relevant to CLIC. Our ATF2 magnet cryostat will have laser view ports for cold mass movement measurement and FF support and stabilization requirements under study. We plan to make stability measurements at BNL and KEK to relate ATF2 FF magnet performance to that of a full length ILC R&D prototype at BNL. We want to be able to predict LC FF performance with confidence. * ATF2 proposal, volumes 1 and 2 at http://lcdev.kek.jp/ILC-AsiaWG/WG4notes/atf2/proposal/index.html |