Kim, K.R.

Paper Title Page
MOPEB014 Status of the PLS-II Magnet Design and Fabrication 307
 
  • D.E. Kim, H.S. Han, Y.-G. Jung, K.R. Kim, H.-G. Lee, S.H. Nam, K.-H. Park, H.S. Suh
    PAL, Pohang, Kyungbuk
 
 

Pohang Light Source (PLS) is planning a major upgrade of the storage ring to meet the more demanding requirement from the synchrotron light users. The main features of the major upgrade are (1) increasing the electron beam energy from 2.5 GeV to 3.0 GeV for more higher energy X-ray photons, (2) decreasing the electron beam emittance from 1.89 nm to 5.8 nm to increase the photon brilliances, and (3) increasing the number of straight sections to install the insertion devices from 10 to 20 to meet the demand for insertion devices. in the upgraded PLS (PLS-II), there will be 24 combined function dipole magnets, 96 quadrupole magnets, and 144 sextupole magnets with some auxiliary magnets for electron beam injection. In this report, the physical design features, mechanical aspects of the magnet design are described.

 
WEPEA052 Magnetic Field Measurement System for PLS-II Magnets 2603
 
  • K.-H. Park, H.S. Han, Y.-G. Jung, D.E. Kim, K.R. Kim, H.-G. Lee, H.S. Suh
    PAL, Pohang, Kyungbuk
  • B.-K. Kang
    POSTECH, Pohang, Kyungbuk
 
 

The PAL (Pohang Accelerator Laboratory) has been carrying out the performance upgrade project, PLS-II. The lattice of the storage ring for PLS-II was changed in whole. The energy was increase from 2.5GeV to 3.0GeV thus many magnets installed in storage ring at present should be replaced with new one or modified. The field of the quadrupole and sextupole magnets will be measured using the rotating coils that are newly fabricated with the engineering ceramic for the first time at PAL. The data acquisition system for the field measurement was also rebuilt to make it simple and to have a good signal to noise ratio. In this presentation, the design parameters of the ceramic rotating coil are described. And various characteristics of the field measurement system are also presented

 
WEPEC046 Design of Superconducting RF System for PLS-II Upgrade 2992
 
  • Y.U. Sohn, S. An, M.-H. Chun, Y.D. Joo, H.-S. Kang, H.-G. Kim, K.R. Kim, C.D. Park, H.J. Park, I.S. Park, I.H. Yu
    PAL, Pohang, Kyungbuk
 
 

The RF system for PLS-II upgrade, of which beam current and emittance are 400 mA and 5.6 nmrad at 3 GeV, becomes much more important compared to PLS. To reduce the HOM intensity in RF cavities for stable beam, a superconducting RF cavity is selected for the PLS-II. The RF system has to compensate beam loss power of 663 kW from 24 bending magnets, 20 insertion devices and other losses by RF HOM and broadband losses along vacuum chambers. For sufficient energy acceptance and lifetime the design RF voltage is 4.5 MV. Three 500 MHz superconducting cavities will be operated from October 2012, following successful commissioning with PLS NC cavities from July 2011. For the 3 SRF cryomodules, a 700 W class He cryogenic system will be prepared in 2011. The design of PLS-II SRF system including cryogenic system will be reported in the paper.

 
WEPD065 Storage Ring Magnet Power Supply System at the PLS-II 3248
 
  • S.-C. Kim, K.R. Kim, S.H. Nam, C.D. Park, Y.G. Son, C.W. Sung
    PAL, Pohang, Kyungbuk
 
 

Lattice of the Storage Ring (SR) is changed from TDB to DBA, and beam energy is enhanced from 2.5 GeV to 3.0 GeV at the Pohang Light Source upgrade (PLS-II). Therefore all magnet specification and number have to change compare with exist PLS SR. At the PLS-II, Magnet Power Supplies (MPS) must be re-designed according to magnet specification of the PLS-II. Newly development MPSs are adopted switching type power conversion technology. High current unipolar MPSs are parallel operation type of unit module buck type power supply, and low current bipolar MPSs are H-bridge type. All MPSs are performed ± 10 ppm output current stability and adopted full digital controller. In this paper, we report on the development and characteristics of the MPS for PLS-II SR.

 
THPE011 Coupling Diagnostics and Control at PLS Storage Ring 4533
 
  • I. Hwang, C. Kim, K.R. Kim, M. Kim, S.H. Nam, S.J. Park, S. Shin
    PAL, Pohang, Kyungbuk
  • J. Hou, L.G. Liu
    SINAP, Shanghai
 
 

The measurement and the control of the coupling is essential to maximize synchrotron performance. Small coupling is required for small vertical size and high brightness. The Pohang Light Source has a 2.5 GeV storage ring and its coupling constant is measured as about 1%. In addition to errors at quadrupole or sextupole, the condition varying of the insertion device affects the coupling. The coupling for various condition is measured by the resonance and the response matrix and compared with the beam size and the lifetime. The correction and the control of the coupling is presented.