A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Hayashizaki, N.

Paper Title Page
MOPEA034 Study of Positron Production System using Superconducting Electron Linac 142
 
  • N. Hayashizaki
    RLNR, Tokyo
  • R. Kuroda, B.E. O'Rourke, N. Oshima, R. Suzuki
    AIST, Tsukuba, Ibaraki
  • E.J. Minehara
    WERC, Tsuruga , Fukui
 
 

Positron that is the antiparticle of the electron, by the specific character, can evaluate vacant spaces in microstructure from atomic level to nanometer level, which is difficult in other measurement methods. In the case of high functional material, this structure often relates directly to the performance, and the evaluation method that uses the positron beam is expected as a useful measurement tool to develop a new material. If it is able to produce more high-intense and low-energy positron beam with an accelerator, the microstructure evaluation is carried out in prompt and high accuracy for various demands of the material analysis. We have studied a positron production system using a superconducting electron linac instead of normal conducting one. Electron beam accelerated with the superconducting linac is irradiated on tantalum and converted to bremstrahlung photons, and positron beam is produced by pair creation of them. The designed acceleration energy of the superconducting electron linac is 15-40 MeV and the maximum beam power is 10 kW. The system configuration and the progress status will be presented.

 
MOPD045 Design and Simulation of C6+ Hybrid Single Cavity Linac for Cancer Therapy 786
 
  • L. Lu, T. Hattori, N. Hayashizaki
    RLNR, Tokyo
 
 

A new type Linac, HSC (hybrid single cavity) linac for cancer therapy, which configuration combines RFQ (Radio Frequency Quadrupole) accelerating structure and DT (Drift Tube) accelerating structure is being finished designs and simulations now. This HSC linac design had adopted advanced power-efficiency-conformation, IH (Interdigital H) structure, which acceleration efficiency is extremely high in the low-middle energy region, and had also adopted most advanced computer simulation technology to evaluate cavity electromagnetic distribution. The study purposes of this HSC linac focus to design of injector linac for synchrotron of cancer radiotherapy facilities. Here, this HSC linac has an amazing space effect because of compact size by coupled complex acceleration electrode and integrated the peripheral device which is made operation easy to handle.

 
THPEC057 Acceleration Test of Two-Beam Type IH-RFQ Linac 4185
 
  • T. Ishibashi, T. Hattori, N. Hayashizaki, L. Liang
    RLNR, Tokyo
 
 

High intensity heavy ion beam acceleration in the low energy region is one of the most difficult conditions to achieve, because the space charge effect is extremely strong. In order to generate a high intensity beam using linacs, we have to avoid beam loss by the space charge effect as much as possible. Multibeam acceleration has been proposed as a possible method of reducing the space charge effect. If one cavity could be used to accelerate several beams, a significant gain would be made in installation space and operational cost saving. In this study we look at a multibeam type radio frequency quadrupole (RFQ) linac in order to accelerate several beams using a single cavity. The RFQ electrodes are placed in an IH type cavity; This structure is known as a IH-RFQ linac. GSI in Germany proposed a multibeam type IH-RFQ linac with several beam channels in a single cavity. However, this multibeam type IH-RFQ linac has yet to be manufactured. We manufactured a 2-beam type IH-RFQ linac as a prototype of the multibeam type IH-RFQ. The linac outputs C2+ beam of 60 keV/u and 44 mA/channel in the design value. We will report about the beam acceleration test of the linac.